摘要 本文从常用的酸碱指示剂的吸收光谱与p H值的关系,以及被滴定对象的酸碱性质入手,用实验的方式研究了强碱滴定强酸、强碱滴定一元弱酸、强碱滴定多元弱酸等多个体系在滴定过程中p H值的变化情况,分析探讨了影响终点误差的诸多因素,这为提高酸碱滴定法的准确度,以及加深对理论课教学中的难点内容——终点误差部分的理解很有帮助。 From the relationship between the absorption spectra of the common acid-base indicator and pH, as well as the acid-base properties of object by titration, it was studied by an experimental way for pH changes of multiple systems such as strong acid, monoprotic weak acid and polyprotic acids in acid base titration. And it was analysised and discussed that the factors influence on the endpoint error. This is very helpful for improving the ac- curacy of acid-base titration, and in-depth understanding of the part of endpoint error, which is the difficult con- tent in the teaching of theory of analytical chemistry.
出处 《化学工程师》 CAS 2016年第1期24-27,30,共5页 Chemical Engineer
基金 宝鸡文理学院第十批校级教改资助项目(No.13JG28)
关键词 终点误差 酸碱滴定法 滴定曲线 酸碱指示剂 吸收光谱 endpoint error acid-base titration titration curve acid-based indicator absorption spectrum