摘要
针对未来2~3年宁夏电网短路水平,通过计算,分析了超标点短路电流增高的主要原因。从网架结构、设备更换及运行方式调整等方面提出了限制措施。应用结果表明:限制措施确保了电网安全稳定运行。
Aiming at the short-circuit level of future 2-3 years in Ningxia power grid, by calculating analyzes the main cause of short-circuit current to increase high for excessive standard points, puts forward restriction measures from the aspects of network structure, equipment change operation mode adjustment. The application result shows that the restriction measures ensure power grid safe and steady operation.
出处
《宁夏电力》
2015年第6期18-20,共3页
Ningxia Electric Power
关键词
电网
短路电流
解环
网架结构
power grid
short-circuit current
loop opening
network structure