摘要
随着G3i采集站使用年限的增加,其故障率也在逐渐增多。文中介绍了G3i采集站使用中出现的加电异常、数据传输异常和无法进行ISP测试等故障现象,分析了其故障原因,并给出了相应的故障排除方法。
With the increasing use of G3i RAM, the failure rate is gradually increasing. This article focus on analyzing several normal faults of the G3i-RAM digital Board. It includes power failure, data transmission failure and ISP failure. Depending on the failure status and test result, this paper analyzed failure reason and gave out effective solutions.
出处
《物探装备》
2015年第6期379-382,共4页
Equipment for Geophysical Prospecting
关键词
G3i-RAM
典型故障
ISP
G3i RAM, common trouble, (ISP)In System Programing