摘要
对均匀墙体表面的红外热谱图的分析表明,均匀墙体表面温度分布符合正态分布,图形是对称的,而非均匀墙体表面温度分布是非对称的,这种非对称性是由缺陷部位造成的,其不对称外延部分越大,缺陷部位影响就越大。本文研究为利用红外热像仪进行建筑热工缺陷研究提供一种新思路。
For the uniform wall surface, an analysis of thermal infrared spectra showed that the temperature distribution of uniform wall surface is based on normal distribution, the graphics are symmetrical, and the temperature distribution of the non-uniform wall surface is not symmetrical, caused by defective parts. The greater asymmetric extension, the greater impact on the defective parts will be. This paper sheds new light on the research on building thermal defect research by using the infrared thermal imager.
出处
《建筑科学》
CSCD
北大核心
2015年第12期34-40,共7页
Building Science
基金
中建股份2012年科技研发计划资助项目"红外热像技术在建筑领域应用的综合研究"
关键词
红外诊断
建筑热工缺陷
定量分析
红外热谱图
正态分布
infrared diagnosis, building thermal defects, quantitative analysis, infrared image, normal distribution