期刊文献+

管内加装波形板扰流件强化对流传热的试验研究 被引量:3

Experimental Study of the Intensified Convection Heat Transfer in a Tube Additionally Installed with Corrugated Plate Flow Disturbers Inside the Tube
原文传递
导出
摘要 采用试验的方法,对装有波形板扰流件的管内高温烟气在小Re数条件下的对流传热及阻力特性进行了研究,并将试验结果分别与无波形板和相关经验公式进行了比较。研究结果表明:管内加装波形板扰流件后,可使高温烟气的对流传热性能得到明显强化,且随着Re数的增大,强化效果越好;波形板扰流件的对流传热强化率为1.6-3.5。根据试验结果总结出1 300<Re<3 500时加装波形板扰流件后管内烟气的对流传热与管子阻力系数的关联式。 By using various test methods,studied were the convective flow heat transfer and resistance characteristics of the flue gases at a high temperature in a tube additionally installed with corrugated plate flow disturbers inside the tube under the condition of the Reynolds number being small and compared were the test results with those obtained in absence of the corrugated plates and calculated by using the empirical formulae respectively. It has been found that after the corrugated plate flow disturbers have been installed inside the tube,the convective flow heat transfer performance of the flue gases at a high temperature can be notably enhanced and with an increase of the Reynolds number,the enhancement effectiveness will become better and better. The convective flow heat transfer enhancement rate of the corrugated plate flow disturbers ranges from 1. 6 to 3. 5. As per the test results,a correlation formula of the heat quantity transferred and resistance coefficient of the tube installed with corrugated plate flow disturbers inside the tube within the test range( 1300 < Re < 3500) was summarized.
出处 《热能动力工程》 CAS CSCD 北大核心 2016年第1期32-36,129-130,共5页 Journal of Engineering for Thermal Energy and Power
关键词 管内对流 雷诺数 波形板扰流件 强化传热 convective flow inside a tube Reynolds number corrugated plate flow disturber enhanced heat transfer
  • 相关文献

参考文献15

  • 1黄功浩,崔乃瑛,陆应生,谭盈科,邓颂九.插入物强化管内单相流体传热的研究[J].化工学报,1983,39(1):23-35. 被引量:18
  • 2王锁芳,高胜勇.低Re数管内强化对流传热实验研究[J].南京航空航天大学学报,1996,28(1):137-140. 被引量:1
  • 3张永福,李方钺.管内螺旋线圈强化传热的研究及在锅炉的应用[J].热能动力工程,1993,8(1):10-14. 被引量:5
  • 4马晓茜,陈烈强.低 Re 数下的强化传热及其方法评价[J].热能动力工程,1998,13(2):143-146. 被引量:3
  • 5Sparrow E M,Hossfeld L M. Effect of rounding of protruding edgeson heat transfer and pressure drop in a duct [ J ] , Int J. Heat MassTransfer, 1984(27) :1715 -1723.
  • 6Sunden B,Skoldheden T. Heat transfer and pressure drop in a newtype of corrugated channels [ J]. International Journal of Heat andMass Transfer,1985(12) :559 -566.
  • 7Paisam Naphon. Effect of corrugated plates in an in-phase arrange-ment on the heat transfer and flow developments [ J ] . InternationalJournal of Heat and Mass Transfer, 2008 ( 51 ) :3963 -3971.
  • 8T. Nishimura, Y. Kawamura. Three-dimensionality of oscillatoryflow in a two-dimensional symmetric sinusoidal wavy-walled chan-nel [ J ] ,Exp. Thermal Fluid Sci’1995(10) :62 -73.
  • 9Bereiziat D,Devienne R. Experimental characterization of Newto-nian and non-Newtonian fluid flows in corrugated channels [ J ].Int. J. Eng. Sci,1999(37) :1461 -1479.
  • 10Stasiek J A. Experimental studies of heat transfer and fluid flowacross corrugated-undulated heat exchanger surfaces [ J ]. Int . J.Heat Mass Transfer, 1998 (41) :899 -914.

二级参考文献13