摘要 对联合站原油罐区存在的火灾、爆炸原因进行了分析,建立了池火灾计算模型。以某联合站内原油罐区为主要研究对象,运用南京安元软件中的池火灾计算模型,模拟发生池火灾事故时可能造成的危害,得出了辐射热通量随距离的变化关系,以及死亡、重伤、轻伤、财产损失和人员安全半径,可为联合站的安全管理和应急救援机制的建立提供理论依据。 In this paper,the causes for fire and explosion in crude oil tank of combined-station are analyzed and pool fire computation model is established.With a crude oil tank inside certain combined-station as the main research object,the pool fire computation model of Nanjing Anyuan software is applied to simulate the hazards that may occur in a pool fire accident.The relationship between the radiant heat flux and distance change are obtained.And the death,serious injury,minor injury,property damage and personnel safety radius are obtained as well.These provide a theoretical basis for the establishment of safety management and emergency rescue mechanism for combined-station.
作者 朱宝军
出处 《石油化工安全环保技术》 CAS 2015年第6期21-22,46,共3页 Petrochemical Safety and Environmental Protection Technology
关键词 池火灾 联合站 安全评价 Pool fire Combined-station Safety assessment
  • 相关文献

参考文献2

  • 1GB50350—2005,油气集输设计规范[S].北京:中国计划出版社,2005.
  • 2陈网桦,王新,等.安全评价师[M].2版.北京:中国劳动社会保障出版社,2010:117-119.