摘要 目的:比较EASI导联心电图在诊断心肌缺血中的临床价值。方法:选择心肌缺血患者200例,均记录其12导联及EASI导联心电图,统计EASI导联组与常规12导联心电图组诊断心律失常效果,及动态心电图检查中的价值与心电图ST-T改变幅度。结果:EASI导联组检出房性早搏、室性早搏、房室传导阻滞及心肌缺血比例高于常规12导联心电图组(P<0.05),EASI导联组发生电极滑脱、基线漂移及肌电干扰比例低于常规12导联心电图组(P<0.05),EASI导联组检出ST-T上抬幅度大于常规12导联心电图组(P<0.05),ST-T下移幅度大于常规12导联心电图组(P<0.05)。结论:EASI导联诊断心肌缺血所受外界干扰小,尤其适用于长时间检查诊断。 Objective: To compare the diagnosis value of EASI lead and 12-lead ECG for myocardial ischemia. Method: 200 cases of patients with myocardial ischemia were simultaneously recorded 12-lead ECG and EASI lead,then the diagnostic effect on arrhythmia,the value of holter electrocardiogranc and the changing maigin of electrocandiogxam ST-T in EASI lead group and 12-lead ECG group were compared. Result: The proportion of occurred atrial premature,premature ventricular contractions,atrioventricular block and the proportion of myocardial ischemia in EASI lead group were higher than those in 12-lead ECG group( P0.05),the proportion of electrode slippage occurs,baseline drift and EMG interference in EASI lead group were lower than those in 12-lead ECG group( P〈0. 05),ST-T elevation amplitude in EASI lead group was significantly higher than that in 12-lead ECG group( P〈0.05),ST-T amplitude down was larger than that in 12-lead ECG group( P〈0.05). Conclusion: The diagnosis with EASI lead for myocardial ischemia has little outside interference,especially suitable for long term diagnosis.
作者 敖雪玲 赵瑞
出处 《河北医学》 CAS 2016年第1期72-75,共4页 Hebei Medicine
基金 甘肃省科研项目 (编号:2011-ZD-11)
关键词 EASI导联 常规12导联 心电图 心肌缺血 EASI Lead 12-Lead ECG Electrocardiogram Myocardial Ischemia
  • 相关文献

参考文献5

  • 1方丕华.EASI导联与常规12导联心电图在心肌缺血诊断中的比较[J].临床心电学杂志,2008,17(3):171-174. 被引量:4
  • 2Petrenas A,Marozas V,Jarusevicius G,et al.A modified Lewis ECG lead system for ambulatory monitoring of atrial arrhythmias[J].Electrocardiol,2015,48(2):157-163.
  • 3张国华,张立涛,张静梅.应用推衍12导联心电图检测术中心肌缺血情况分析[J].中国骨肿瘤骨病,2008,7(2):123-124. 被引量:2
  • 4Sejersten M,Wagner GS,Pahlm O,et al.Detection of acute ischemia from the EASI-derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice[J].Electrocardiol,2007,40(12):120-126.
  • 5Finlay DD,Nugent CD,Nelwan SP,et al.Effects of electrode placement errors in the EASI-derived 12-lead electrocardiogram[J].Electrocardiol,2010,43(6):606-611.

二级参考文献8

  • 1[1]安刚,薛富善主编 .现代麻醉学技术 .北京:科学技术文献出版社,2001: 526-529
  • 2[1]Wehr G,Peters R J,Khalife K.A vector-based,5-electrode,12-lead monitoring ECG (EASI) is equivalent to conventional 12-lead ECG for diagnosis of acute coronary syndromes.J Electrocardiol,2006.39:22-28.
  • 3[2]Chantad D,Krittayaphong R,Komoltri C.Derived 12-lead electrocardiogram in the assessment of ST-segment deviation and cardiac rhythm.J Electrocardiol,2006,39:7-12.
  • 4[3]Sejersten M,Wagner G S,Pahlm O,et al.Detection of acute ischemia from the EASI.derived 12-lead electrocardiogram and from the 12-lead electrocardiogram acquired in clinical practice.J Electrocardiol,2007,40:120-126.
  • 5[5]Dower G E,Machado H B,Osborne J A.On deriving the electrocardiogram from vectorcardiographic leads.Clin Cardiol,1980,3:87-95.
  • 6[6]Dower G E,Yakush A,Nazzal S B.Deriving the 12-lead electrocardiogram from four (EASI) electrodes.J Electrocardiol,1988,21 (Suppl):S182-S187.
  • 7[7]Feild D Q,Feldman C L,Horacek B M.Improved EASI coefficients:their derivation,values,and performance.J Electrocardiol,2002,35 (Suppl):23-33.
  • 8[8]Mangano D T,Layug E L,Wallace A,et al.Effect of atenolol on mortality and cardiovascular morbidity after noncardiac surgery.Multicenter Study of Perioperative Ischemia Research Group.N Engl J Med,1996,335:1713.

共引文献3

同被引文献96

引证文献12

二级引证文献112

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部