概述PET装置USG600型水下切粒机的工作原理及其电控系统的结构特点,结合典型故障现象进行原因分析,并提供了有效的处理措施。
The working principle and the structure characteristics of the electric control system of PET plant USG600 underwater pelletizing machine were overviewed. Combination with the typical fault phenomenon, the reasons were analysed, the effective treatment measures were provided.