摘要
采用活性碳吸附,二硫化碳解吸进样,利用HP-Innowax毛细柱,以FID检测器测定乙酸丁酯。本研究基于GBZ/T160.63-2007方法,通过实验测试,修改了部分仪器条件,大大提高了测定乙酸丁酯的工作效率。
In this study, Using activated carbon adsorption, carbon disulfide desorption sampling, butyl acetate were measured by FID detector through HP-Innowax capillary column. Through modifying some conditions of the instrument, determination of butyl acetate can greatly improve work efficiency.
出处
《环境与发展》
2015年第5期89-90,共2页
Environment & Development
关键词
气相色谱
乙酸丁酯
Butyl acetate
Gas chromatography