期刊文献+

Efficacy and economic analysis of Ex- PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a systematic review and Meta-analysis 被引量:5

Efficacy and economic analysis of Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a systematic review and Meta-analysis
下载PDF
导出
摘要 AIM:To systematically review the current evidence based on the efficacy and cost of Ex-PRESS implantation and trabeculectomy(Trab)for uncontrolled glaucoma.·METHODS:Clinical trials were identified by electronic databases(Pub Med,EMBASE,ISI Web of science and Cochrane library),and data,such as intraocular pressure(IOP),the complete and qualified success rate,the postoperative complications and the cost,were exacted from these relevant studies.Weighted mean difference(WMD),odds ratio(OR)and 95%confidence intervals(CIs)were calculated and were pooled using a randomeffects model.·RESULTS:Eleven relevant publications and two abstracts met the inclusion criteria.The efficacy of ExPRESS was similar to that of Trab in the percentage of IOP reduction(IOPR%)at 1,2y(WMD:-2.01;95%CI:-7.92-3.90;=0.50 and WMD:2.89;95%CI:-8.05-13.83;=0.60,respectively).Ex-PRESS possessed a significant higher complete and qualified success rate(OR:1.59;95%CI:1.07-2.35;=0.02 and OR:1.74;95%CI:1.06-2.86;=0.03,respectively).Moreover,Ex-PRESS exerted a significantly lower frequency of hypotony and hyphema than Trab(OR:0.39;95%CI:0.21-0.72;=0.003 and OR:0.27;95%CI:0.10-0.69;=0.003,respectively).However,there was no consistent result on the cost between the two groups according to the previous three studies.·C ONCLUSION:Both Trab and Ex-PRESS have equivalent efficacy in lowering IOP,yet Ex-PRESS had a lower risk of hypotony and hyphema than Trab.Nevertheless,whether the cost of Ex-PRESS was less than that of Trab should be further investigated to ensure evidence-based conclusion in the long run. AIM:To systematically review the current evidence based on the efficacy and cost of Ex-PRESS implantation and trabeculectomy(Trab)for uncontrolled glaucoma.·METHODS:Clinical trials were identified by electronic databases(Pub Med,EMBASE,ISI Web of science and Cochrane library),and data,such as intraocular pressure(IOP),the complete and qualified success rate,the postoperative complications and the cost,were exacted from these relevant studies.Weighted mean difference(WMD),odds ratio(OR)and 95%confidence intervals(CIs)were calculated and were pooled using a randomeffects model.·RESULTS:Eleven relevant publications and two abstracts met the inclusion criteria.The efficacy of ExPRESS was similar to that of Trab in the percentage of IOP reduction(IOPR%)at 1,2y(WMD:-2.01;95%CI:-7.92-3.90;=0.50 and WMD:2.89;95%CI:-8.05-13.83;=0.60,respectively).Ex-PRESS possessed a significant higher complete and qualified success rate(OR:1.59;95%CI:1.07-2.35;=0.02 and OR:1.74;95%CI:1.06-2.86;=0.03,respectively).Moreover,Ex-PRESS exerted a significantly lower frequency of hypotony and hyphema than Trab(OR:0.39;95%CI:0.21-0.72;=0.003 and OR:0.27;95%CI:0.10-0.69;=0.003,respectively).However,there was no consistent result on the cost between the two groups according to the previous three studies.·C ONCLUSION:Both Trab and Ex-PRESS have equivalent efficacy in lowering IOP,yet Ex-PRESS had a lower risk of hypotony and hyphema than Trab.Nevertheless,whether the cost of Ex-PRESS was less than that of Trab should be further investigated to ensure evidence-based conclusion in the long run.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第1期124-131,共8页 国际眼科杂志(英文版)
基金 Supported by the National Natural Science Foundation of China(No.81373826)
关键词 Ex-PRESS implantation TRABECULECTOMY uncontrolled glaucoma systematic review META-ANALYSIS Ex-PRESS implantation trabeculectomy uncontrolled glaucoma systematic review Meta-analysis
  • 相关文献

参考文献24

  • 1Quigley HA, Broman AT. The number of people with glaucoma worldwide in 2010 and 2020. Dr JOphthalmoJ2006;90(3):262-267.
  • 2Patel HY, Wagschal LO, Trope GE, Buys YM. Economic analysis of the Ex-PRESS miniature glaucoma device versus trabeculectomy .I CLluconM 2014;23(6):385-390.
  • 3Rouse JM, Sarkisian SR Jr. Mini-drainage devices: the Ex-PRESS mini-glaucoma device.JCT OphlhalmoI2012;50:90-95.
  • 4de Jong LA, Lafuma A, Aguade AS, Clement 0, Berdeaux G. PM036 cost-effectiveness of the ex-press glaucoma filtration device in the Netherlands. Viuuell HeiItL 2011;14(7):A250.
  • 5de Jong LA, Lafuma A, Clement 0, Aguade AS, Berdeaux G. PM037 cost-effectiveness of the ex-press glaucoma filtration device in France. I aitltelIlt?alth 2011;14(7):A250-A251.
  • 6Downs SH, Black N. The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions.I l0idemiol CummUlJitv Health 1998;52(6):377-384.
  • 7Follmann D, Elliott P, Suh I, Cutler]. Variance imputation for overviews of clinical trials with continuous response .I aI epidtemlo1992;45 (7): 769-773.
  • 8Higgins JP, Thompson SG, Deeks 11, Altman DG. Measuring inconsistency in meta-analyses. 8HJ2003;327(7414):557-560.
  • 9de Jong L, Lafuma A, Aguade AS, Berdeaux, G. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. CIIl1 OphlhalmoI2011;5: 527-533.
  • 10Wagschal LO, Trope GE, Jinapriya 0, Iin YP, Buys YM. Prospective randomized study comparing Ex- PRESS to trabeculectomy: I-year results.I Chacoma 2015 ;24(8):624-629.

同被引文献34

引证文献5

二级引证文献30

相关作者

内容加载中请稍等...

相关机构