期刊文献+

ATP生物荧光法对口腔器械清洗和医务人员手卫生质量的评价 被引量:19

Evaluation on clean quality of oral instruments and medical personnel hands hygiene with ATP bioluminescence method
原文传递
导出
摘要 目的研究ATP生物荧光法对口腔器械的清洗和医务人员手卫生质量评价的实用性,建立清洗效果快速评价方法。方法运用ATP生物荧光法,以个体口腔诊所为对象,建立口腔器械清洗和医护人员手卫生质量快速评价方法。结果国产仪器检测牙钻手机清洗质量合格率为93.33%,检测探针清洗合格率为100%;工作状态下和洗手后手卫生质量合格率均为100%。美国进口仪器检测牙钻手机和探针清洗合格率分别为46.67%和60.00%;工作状态下和洗手后手卫生质量合格率分别为18.42℅和68.42%。结论用国产和进口ATP生物荧光检测仪评价个体口腔诊所口腔器械医护人员手清洗质量,结果差异明显,仍需要进行进一步研究。 Objective To research the practicability of evaluation of clean quality of oral instruments and medical personnel hands hygiene with ATP bioluminescence method,to establish rapid assessment method of cleaning effect. Methods ATP bioluminescence method was used to establish rapid assessment method of clean quality of oral instruments and medical personnel hands hygiene by make the individual dental clinics as the object. Results The qualified rates of toothdrill handpiece and the probe were 93. 33% and 100% respectively,the qualified rates of medical personnel's hands hygiene in service and in clean condition were both 100%,which were detected by Chinese instrument. The qualified rates of toothdrill handpiece and the probe were 46. 67% and 60. 00% respectively,the qualified rates of medical personnel hands hygiene in service and in clean condition were 18. 42% and 68. 42% respectively,which were detected by import instrument. Conclusion Using Chinese instrument and import instrument to evaluate the clean quality of oral instruments and medical personnel's hands hygiene,had obvious difference and still need further study.
出处 《中国消毒学杂志》 CAS 北大核心 2016年第1期34-35,38,共3页 Chinese Journal of Disinfection
关键词 口腔诊所 手卫生 医疗器械 清洗质量 生物荧光法 检测 dental clinic hand hygiene medical instrument cleaning quality ATP bioluminescence method detection
  • 相关文献

参考文献7

二级参考文献28

  • 1谭琳玲,李亚洁,李瑛.将感染控制在“手”中——手部卫生与医院感染[J].中国医院管理,2005,25(5):21-23. 被引量:47
  • 2韩黎,朱士俊,郭燕红,李六亿,胡必杰,武迎宏,袁云娥.中国医务人员执行手卫生的现状调查[J].中华医院感染学杂志,2006,16(2):140-142. 被引量:631
  • 3医院感染管理办法[J].中国护理管理,2006,6(7):5-7. 被引量:42
  • 4刘葆华,易小梅,詹德群,康霞.医院使用租赁手术器械现状调查[J].中华医院感染学杂志,2006,16(8):896-896. 被引量:123
  • 5Raboud J,Saskin R,Wong K,et al.Patterns of handwashing behavior and visits to patients on a general medical ward of healthcare workers.Infect Con Hospit Epidemiol,2004,25(3):198-202.
  • 6William AR, David JW. Guideline for disinfection and sterilization in heahhcare facilities[S]. Healtheare Infection Control Practices Advisory Committee, 2008 : 36.
  • 7王羽.医院感染管理办法释义及适用指南.北京:中国法制出版社,2006:156-178.
  • 8Hansen D.ATP measurement as method to monitoring the quality of reprocessing flexible endoscopes[J].German Medical Science.2004,2:4.
  • 9Lehtinen J.Virta M,Lilius EM.Fluoro-Luminometric real-time measurement of bacterial viability and Killing[J].J Microbiol Methods.2003,55:173.
  • 10Gu MB,Min J,Larossa RA.Bacterial bioluminescence emission from recombinant Escherichia coil harboring a reca:luxCDABE fusion[J].J Biochem Biophys Methods.2000,45(1):45.

共引文献223

同被引文献169

引证文献19

二级引证文献113

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部