A spectrometer for measuring particle size distributions in the range of 3 nm to 10 μm 被引量:3

A spectrometer for measuring particle size distributions in the range of 3 nm to 10 μm
原文传递
导出
摘要 A spectrometer combining electrical mobility sizing and aerodynamic sizing was developed to measure aerosol size distributions in the range of 3 nm to 10 μm. It includes three instruments which cover different size ranges (a nano scanning mobility particle sizer (NSMPS, 3 - 60 nm), a regular scanning mobility particle sizer (RSMPS, 40 - 700nm), and an aerodynamic particle sizer (APS, 550nm- 10 μm)). High voltage and sheath flow of the NSMPS and RSMPS were supplied using two home-built control boxes. A LabVIEW program was developed for spectrometer automatic operation. A linear inversion method was applied to correct particle multiple charging effects and to integrate data from the three instruments into a wide-range size distribution. Experi- ments were conducted to compare distributions in the overlap size ranges measured by three instruments. Good agreement between the NSMPS and RSMPS was achieved after correcting for the difference in counting efficiencies of the two particle counters. Aerodynamic size distribu- tions reported by the APS were converted to mobility size distributions by applying an effective density method. Distributions measured by the RSMPS and APS were consistent in the overlap size range of 550 - 700 nm. A full spectrum in the size range of 3nm to 10~tm was demonstrated by measuring aerosol generated using a mixture of different sized polystyrene latex spheres. A spectrometer combining electrical mobility sizing and aerodynamic sizing was developed to measure aerosol size distributions in the range of 3 nm to 10 μm. It includes three instruments which cover different size ranges (a nano scanning mobility particle sizer (NSMPS, 3 - 60 nm), a regular scanning mobility particle sizer (RSMPS, 40 - 700nm), and an aerodynamic particle sizer (APS, 550nm- 10 μm)). High voltage and sheath flow of the NSMPS and RSMPS were supplied using two home-built control boxes. A LabVIEW program was developed for spectrometer automatic operation. A linear inversion method was applied to correct particle multiple charging effects and to integrate data from the three instruments into a wide-range size distribution. Experi- ments were conducted to compare distributions in the overlap size ranges measured by three instruments. Good agreement between the NSMPS and RSMPS was achieved after correcting for the difference in counting efficiencies of the two particle counters. Aerodynamic size distribu- tions reported by the APS were converted to mobility size distributions by applying an effective density method. Distributions measured by the RSMPS and APS were consistent in the overlap size range of 550 - 700 nm. A full spectrum in the size range of 3nm to 10~tm was demonstrated by measuring aerosol generated using a mixture of different sized polystyrene latex spheres.
出处 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2016年第1期63-72,共10页 环境科学与工程前沿(英文)
基金 We thank Dr. James Smith for his assistance on designing the control box and Ms. Zhiying Xie for her help on setting up the spectrometer. Financial supports from the National Natural Science Foundation of China (Grant Nos: 41227805, 21107060, 21190054 and 21221004), National Key Basic Research and Development Program of China (Grant No: 2013CB228505), and Beijing Natural Science Foundation (8122025) are acknowledged.
关键词 SPECTROMETER particle size distribution elec-trical mobility aerodynamic diameter linear inversion spectrometer, particle size distribution, elec-trical mobility, aerodynamic diameter, linear inversion
  • 相关文献

参考文献1

二级参考文献25

  • 1WTO. Air quality guidelines-global update 2005 [ R]. WTO,2005.
  • 2IPCC. Climate Change 2007 : IPCC Fourth Assessment Report(AR4) [ R]. Cambridge: Cambridge University Press, 2007.
  • 3Pope C A, Ezzati M, Dockery D W. Fine-particulate airpollution and life expectancy in the United States [ J]. NewEngland Journal of Medicine, 2009,360(4) : 376-386.
  • 4Jiang J K, Oberdfirster G, Biswas P. Characterization of size,surface charge, and agglomeration state of nanoparticledispersions for toxicological studies[ J] . Journal of NanoparticleResearch, 2009, 11(1) : 77-89.
  • 5Oberdbrster G, Oberdttrster E,Oberdorster J. Nanotoxicology:an emerging discipline evolving from studies of ultrafine particles[J]. Environmental Health Perspectives, 2005 , 113(7): 823-839.
  • 6Jiang J K,Attoui M,Heim M,et al. Transfer functions andpenetrations of five differential mobility analyzers for Sub- 2 nmparticle classification [ J]. Aerosol Science and Technology,2011,45(4) : 480-492.
  • 7Jiang J K, Chen M D,Kuang C A, et al. Electrical mobilityspectrometer using a diethylene glycol condensation particlecounter for measurement of aerosol size distributions down to 1 nm[J] . Aerosol Science and Technology, 2011,45(4) ; 510-521.
  • 8Kulkami P, Baron P A, Willeke K. Aerosol Measurement :Principles, Techniques, and Applications [ M]. (3rd ed.).New York : Wiley-lnterscience,2011. 449-474.
  • 9Jiang J K, Hogan C J, Chen D R, ef al. Aerosol charging andcapture in the nanoparticle size range (6-15 nm) by directphotoionization and diffusion mechanisms[ J]. Journal of AppliedPhysics, 2007,102(3) : 34904,doi:10. 1063/1.2768061.
  • 10Jiang J K, Chen D R, Biswas P. Synthesis of nanoparticles in aflame aerosol reactor with independent and strict control of theirsize, crystal phase and morphology[ J] . Nanotechnology, 2007 ,18(28) : 285603,doi:10.1088/0957-4484/18/28/285603.