期刊文献+

In-situ characterization of electrochromism based on ITO/PEDOT:PSS towards preparation of high performance device

In-situ characterization of electrochromism based on ITO/PEDOT:PSS towards preparation of high performance device
下载PDF
导出
摘要 Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)(PEDOT:PSS) is usually sandwiched between indium tin oxide(ITO) and a functional polymer in order to improve the performance of the device. However, because of the strong acidic nature of PEDOT:PSS, the instability of the ITO/PEDOT:PSS interface is also observed. The mechanism of degradation of the device remains is unclear and needs to be further studied. In this article, we investigate the in-situ electrochromism of PEDOT:PSS to disclose the cause of the degradation. X-ray photoelectron spectroscopy(XPS) was used to characterize the PEDOT:PSS films, as well as the PEDOT:PSS plus polyethylene glycol(PEG) films with and without indium ions. The electrochromic devices(ECD) based on PEDOT:PSS and PEG with and without indium ions are carried out by in-situ micro-Raman and laser reflective measurement(LRM). For comparison, ECD based on PEDOT:PSS and PEG films with LiCl, KCl, NaCl or InCl_3 are also investigated by LRM. The results show that PEDOT:PSS is further reduced when negatively biased, and oxidized when positively biased. This could identify that PEDOT:PSS with indium ions from PEDOT:PSS etching ITO will lose dopants when negatively biased. The LRM shows that the device with indium ions has a stronger effect on the reduction property of PEDOT:PSS-PEG film than the device without indium ions. The contrast of the former device is 44%, that of the latter device is about 3%. The LRM also shows that the contrasts of the device based on PEDOT:PSS+PEG with LiCl, KCl, NaCl, InCl_3 are 30%, 27%, 15%, and 18%, respectively. Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)(PEDOT:PSS) is usually sandwiched between indium tin oxide(ITO) and a functional polymer in order to improve the performance of the device. However, because of the strong acidic nature of PEDOT:PSS, the instability of the ITO/PEDOT:PSS interface is also observed. The mechanism of degradation of the device remains is unclear and needs to be further studied. In this article, we investigate the in-situ electrochromism of PEDOT:PSS to disclose the cause of the degradation. X-ray photoelectron spectroscopy(XPS) was used to characterize the PEDOT:PSS films, as well as the PEDOT:PSS plus polyethylene glycol(PEG) films with and without indium ions. The electrochromic devices(ECD) based on PEDOT:PSS and PEG with and without indium ions are carried out by in-situ micro-Raman and laser reflective measurement(LRM). For comparison, ECD based on PEDOT:PSS and PEG films with LiCl, KCl, NaCl or InCl_3 are also investigated by LRM. The results show that PEDOT:PSS is further reduced when negatively biased, and oxidized when positively biased. This could identify that PEDOT:PSS with indium ions from PEDOT:PSS etching ITO will lose dopants when negatively biased. The LRM shows that the device with indium ions has a stronger effect on the reduction property of PEDOT:PSS-PEG film than the device without indium ions. The contrast of the former device is 44%, that of the latter device is about 3%. The LRM also shows that the contrasts of the device based on PEDOT:PSS+PEG with LiCl, KCl, NaCl, InCl_3 are 30%, 27%, 15%, and 18%, respectively.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第2期517-521,共5页 中国物理B(英文版)
基金 Project supported by the National High Technology Research and Development Program of China(Grant No.2015AA034201) the Chinese Universities Scientific Fund(Grant No.2015LX002)
关键词 PEDOT:PSS ELECTROCHROMISM electrochromic devices INTERFACE PEDOT:PSS, electrochromism, electrochromic devices, interface
  • 相关文献

参考文献25

  • 1Burroughes J H, Bradley D D C, Brown A R, Marks R N, Mackay K, Friend R H, Burns P L and Holmes A B 1990 Nature 347 539.
  • 2Carter S A, Angelopoulos M, Karg S, Brock P J and Scott J C 1997 Appl. Phys. Lett. 70 2067.
  • 3Hao Z H, Hu Z Y, Zhang J J, Hao Q Y and Zhao Y 2011 Acta Phys. Sin. 60 117106 (in Chinese).
  • 4Hou T, Liang C J, Zhang F J, He Z Q and Sun K 2014 Chin. Phys. Lett. 31 028801.
  • 5Zhuo Z L, Wang Y S, He D W and Fu M 2014 Chin. Phys. B 23 098802.
  • 6Kim Y, Ballantyne A M, Nelson J and Bradley D D C 2009 Organic Electronics 10 205.
  • 7Xing Y J, Qian M F, Guo D Z and Zhang G M 2014 Chin. Phys. B 23 038504.
  • 8Feng Z H, Hou Y B, Shi Q M, Qin L F, Li Y, Zhang L, Liu X J, Teng F, Wang Y S and Xia R D 2010 Chin. Phys. B 19 038601.
  • 9Hao J Y, Xu Y, Zhang Y P, Chen S F, Li X A, Wang L H and Huang W 2015 Chin. Phys. B 24 045201.
  • 10Liu Z F, Zhao S L, Xu Z, Yang Q Q, Zhao L, Liu Z M, Chen H T, Yang Y F, Gao S and Xu X R 2014Acta Phys. Sin. 63 068402 (in Chinese).

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部