本文从建筑电气系统设计中常用的微型断路器选型问题入手,分析了环境温度、安装条件对微型断路器的降容影响,针对不同性质的负荷如何选择相应的断路器及对微型断路器接线中出现的问题提出了一些建议,供设计人员参考。
This paper starts with the selection of miniature circuit-breakers used in the design of building electrical system.,The influence of environmental temperature and installation conditions on the drop capacity of the miniature circuit-breaker is analyzed.Some suggestions are put forward for the design of the corresponding miniature circuit-breaker for different nature of load and the problem of the connection to the miniature circuit breaker.
出处
《中国建材科技》
2015年第6期122-123,共2页
China Building Materials Science & Technology
关键词
降容
脱扣特性
接线
drop capacity
tripping characteristics