根据某工程具体实践,从施工组织管理、浇筑施工工艺、混凝土养护措施方面讲述大体积混凝土裂缝的防治措施。提出施工现场有效控制措施——温度监测,针对提高测温成功率的难点,设计出一种新型测温保护装置,并介绍了新装置的具体施工方法,有效地保证了测温记录的完整性和真实性。
Based on a project construction,the prevention measures of mass concrete are described from construction organization management, pouring construction process, concrete maintenance measures. The effective temperature control measures temperature monitoring is put forward. A new temperature monitoring protect equipment is designed to solve the method is introduced. The completeness and authenticity difficulties of monitoring, and its construction of monitoring record is guaranteed.