期刊文献+

ICP–AES法测定低合金钢中的微量硼 被引量:6

Determination of Trace Boron in Low-Alloy Steel by Inductively Coupled Plasma Atomic Emission Spectrometry
下载PDF
导出
摘要 采用电感耦合等离子体发射光谱法(ICP–AES) 测定低合金钢中硼元素的含量.采用密闭微波消解法对样品进行溶解,考察了铁基体元素和共存元素对硼元素测定的影响,确定了硼元素的分析线为208.959 nm,通过基体匹配消除基体的影响.硼的质量浓度在0~5.00 μg/mL 范围内与谱线强度呈良好的线性,相关系数r^2=0.999 9,方法检出限为0.004 μg/mL,加标回收率为96%~103%,测定结果的相对标准偏差为1.5%~2.9%(n=8).该方法具有较高的灵敏度和准确度,满足低合金钢中硼元素的分析要求. The content of boron in low-alloy steel was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sample was decomposed in microwave digestion instrument. The interference from matrix and co-existing elements were studied. The analysis line of boron was set on 208.959 nm. The matrix effect was corrected by matrix matching. The concentration of boron was linear with intensity of spectral line in the range of 0-5.00 μg/mL, with correlations coefficient (r2) of 0.999 9. The detection limit was 0.004 μg/mL,the recovery rate was 96%-103% and the relative standard deviation of determination results was 1.5%-2.9%(n=8). The method has good sensitivity and accuracy, which can be used in the determination of boron in low-alloy steel.
出处 《化学分析计量》 CAS 2016年第1期47-49,共3页 Chemical Analysis And Meterage
关键词 低合金钢 电感耦合等离子体光谱法 微波消解 low-alloy steel boron inductively coupled plasma atomic emission spectrometry(ICP–AES) microwave digestion
  • 相关文献

参考文献12

  • 1佴启亮,郑文杰,宋志刚,陈清明,丰涵.硼含量对含硼不锈钢组织和性能的影响[J].钢铁研究学报,2013,25(6):53-57. 被引量:22
  • 2GB/T 223.6–1994 钢铁及合金化学分析方法 中和滴定法测定硼量[S].
  • 3杨竞,张秀华,田志宏,徐晓云,刘军.酸碱滴定法测定硅质耐火材料中硼[J].冶金分析,2014,34(4):78-80. 被引量:7
  • 4GB/T 223.75–2008 钢铁及合金硼含量的测定 甲醇蒸馏–姜黄素光度法[S].
  • 5GB/T 223.78–2000 钢铁及合金化学分析方法 姜黄素直接光度法测定硼含量[S].
  • 6GB/T 223.81–2007 钢铁及合金总铝和总硼含量的测定 微波消解– 电感耦合等离子体质谱法[S].
  • 7杨贤,张洁,蔡金芳,王强.电感耦合等离子体质谱法测定地质样品中硼[J].冶金分析,2014,34(6):7-10. 被引量:13
  • 8Fujimoto K, Fujimoto M, Shimura, S. Determination of traceamounts of antimony and boron in high-purity iron andsteel by isotope dilution/inductively coupled plasma massspectrometry[J]. Mater Trans, 2002, 43: 101–104.
  • 9Coedo A G, Dorado M T, Padilla I. Comparative study of sparkablation and pneumatic nebulization sampling systems[J].Spectrochim Acta, Part B, 2005, 60: 73–79.
  • 10GB/T 20125–2006 低合金钢 多元素含量的测定 电感耦合等离子体原子发射光谱法[S].

二级参考文献60

共引文献49

同被引文献44

引证文献6

二级引证文献40