期刊文献+

基于小波变换的容积脉搏波信号去噪研究 被引量:7

Research on The Plethysmogphic Pulse Wave Signal De-noising Based on Wavelet Transform
下载PDF
导出
摘要 在容积脉搏波信号采集过程中,会受到多种噪声干扰,传统的去噪处理效果并不理想。经过理论分析各种小波基特点得出适合处理容积脉搏波的最佳小波基,通过使用传感器采集的信号进行验证,采用分层阈值去噪的方法,提出对比去噪后信号的二阶微分信号作为去噪性能评定指标,最后得出coif5小波基在抑制噪声的同时还能保留容积脉搏波信号的特征便于进行后期研究。 In the process of plethysmogphic pulse wave signal acquisition , it will be affected by a variety of noise interference, the traditional de-noising processing effect is not ideal. In this paper, through analysis of wavelet base features to find the best suitable wavelet base for plethysmogphic pulse wave de-nosing. Validated by using a sensor to collect signal, using the hierarchical threshold de-noising method, and put forward contrast de-noising signal's second-order differential wave as a denoising performance index, the finally concluded is that coif5 wavelet base in suppressing noise at the same time also can reserve plethysmogphic pulse wave signal feature for further study.
作者 龙雨 朱希安
出处 《科技通报》 北大核心 2016年第1期141-144,共4页 Bulletin of Science and Technology
基金 国家科技重大专项煤层气田地面集输信息集成及深度开发技术(2011ZX05039-004-02) 北京信息科技大学研究生科技创新项目(5121424102)
关键词 容积脉搏波 PPG 小波变换 阈值函数 去噪 plethysmogphic pulse wave PPG wavelet transform threshold function de-noising
  • 相关文献

参考文献7

二级参考文献45

  • 1张泾周,寿国法,戴冠中.基于小波变换的心电信号噪声处理[J].西北工业大学学报,2005,23(1):11-14. 被引量:24
  • 2向海燕,俞梦孙.用脉搏波传导时间实现血压连续测量[J].医疗卫生装备,2006,27(2):19-21. 被引量:31
  • 3李建新,金印彬.小波变换在心电信号滤波器中的应用研究[J].微计算机信息,2006,22(07S):294-295. 被引量:2
  • 4李立霞,王文博,王德隽.子波变换去噪的一种新算法[J].信号处理,1996,12(3):261-266. 被引量:20
  • 5Goodman T N T, Lee S L. Wavelets of multiplicity[J]. Trans. on Amer. Math Soc,1994,342(1):307-324.
  • 6Donoho D L. De-noising by soft-thresholding[J]. IEEE Transactions on Information Theory, 1995,41 (3):613-627.
  • 7AOYAGI T, FUSE M, KOBAYASHI N, et al. Multiwave- length pulse oximetry: theory for the future [J]. Anesth Analg, 2007, 105(6 Suppl): S53-S58.
  • 8WIERINGA F P, MASTIK F, VAN DER STEEN A F. Contactless multiple wavelength photoplethysmographic ima- ging: a first step toward "SpO2 camera" technology[J]. Ann Biomed Eng, 2005, 33(8) : 1034-1041.
  • 9SUN Y, PAPIN C, AZORIN-PERIS V, et al. Use of ambi- ent light in remote photoplethysmographic systems., compari- son between a high-performance camera and a low-cost web- cam[J]. J Biomed Opt, 2012, 17(3) :037005.
  • 10NONNENMACHER A, HOPP H, DUDENHAUSEN J. Predictive value of pulse oximetry for the development of fetal acidosis[J]. J Perinat Med, 2010, 38(1): 83-86.

共引文献62

同被引文献63

引证文献7

二级引证文献14