金属增感屏在同感光度双胶片技术中的应用 被引量:1

Application of Metal Intensifying Screen to the Double-film Technology with Equal Exposure Sensitivity
下载PDF
导出
摘要 以钛合金阶梯试块为对象,以底片像质计灵敏度和黑度为评估指标,对相同感光度的双胶片和增感屏的不同组合方式进行研究。结果表明:按航标HB/Z60《X射线照相检验》中的规定,对最大厚度小于42mm的零部件,若被检测零件的最大厚度与最小厚度的比值小于5.5,胶片放置可采用MX125 MX125的组合方式;若被检测零件的最大厚度与最小厚度的比值小于3.0,胶片放置可采用MX125、MX125和AA400 AA400的组合方式。 In the present work,with the film sensitivity and film density as evaluation parameters,the combination patterns of double-film technology with metal intensifying screen were studied with titanium alloy step blocks.The results show that in accordance with the regulation of HB/Z60《Radiographic Inspection》,for the parts of thickness being less than 42 mm :if the maximum and minimum thickness ration of detected part is less than 5.5,the combination pattern of MX125 MX125 can be used,if the ration is less than 3.0,the combination pattern of MX125,MX125 and AA400 AA400 can be used.
出处 《无损检测》 2016年第1期17-19,25,共4页 Nondestructive Testing
关键词 金属增感屏 双胶片技术 X射线检测 组合方式 评估指标 Metal intensifying screen Double-film technology Radiographic inspection Combination pattern Evaluation index