摘要
通过实验室与核电站应用比较了邻菲罗啉和蓝点法两种不锈钢钝化膜的显色检测特征。实验室对比分析表明邻菲罗啉溶液较蓝点溶液具有较高的稳定性,而蓝点溶液会造成不锈钢表面的潜在损伤。核电不锈钢阀门检查结果表明蓝点溶液检测灵敏度波动性较大,与实验结果一致。因此邻菲罗啉溶液在核电站不锈钢设备钝化膜评估中具有更高的适用性。
This paper expounds the color-change detection characteristic on stainless steel passivation films with the laboratory result and application in nuclear power plants. Compared with the blue point solution, the Ferroin solution has higher stability according to Laboratory comparative analysis, and the blue spot solution can cause the surface damage of the stainless steel. Stainless steel valve results agree with experimental results show that the sensitivity of blue point solution decreased significantly.Therefore, It is proposed that the Ferroin solution is superior to blue dot solution during the evaluation on stainless steel facilities in nuclear power plants.
出处
《全面腐蚀控制》
2016年第1期28-32,共5页
Total Corrosion Control
关键词
不锈钢
钝化膜
显色检测
核电站
stainless steels
passive film
color-change detection
nuclear power plant