摘要 The use of minus identity lenses with an angle-cut collimator can achieve high contrast images in highenergy proton radiography.This article presents the principles of choosing the angle-cut aperture of the collimator for different energies and objects.Numerical simulation using the Monte Carlo code Geant4 has been implemented to investigate the entire radiography for the French test object.The optimum angle-cut apertures of the collimators are also obtained for different energies. The use of minus identity lenses with an angle-cut collimator can achieve high contrast images in highenergy proton radiography.This article presents the principles of choosing the angle-cut aperture of the collimator for different energies and objects.Numerical simulation using the Monte Carlo code Geant4 has been implemented to investigate the entire radiography for the French test object.The optimum angle-cut apertures of the collimators are also obtained for different energies.
作者 许海波 郑娜
出处 《Chinese Physics C》 SCIE CAS CSCD 2016年第2期102-106,共5页 中国物理C(英文版)
基金 Supported by NSAF(11176001) Science and Technology Developing Foundation of China Academy of Engineering Physics(2012A0202006)
关键词 proton radiography multiple Coulomb scattering angular collimator French test object Geant4 proton radiography multiple Coulomb scattering angular collimator French test object Geant4
  • 相关文献

参考文献1

二级参考文献15

  • 1Boyd T J.A pulsed high-energy radiographic machine emitting X-rays[R].LA-3241,1967.
  • 2Burns M J,Carlston B E,Kwan T J T,et al.Durht accelerators update and plans for initial operation[C]//Proceedings of 1999 Particle Accelerator Conference.1999,1:617-621.
  • 3Schneider U,Pedroni E.Proton radiography as a tool for quality control in proton therapy[J].Medical Physics,1995,22(4):353-363.
  • 4Morris C L.Proton radiography for an advanced hydrotest facility[R].LA-UR-00-5716,2000.
  • 5Meitzner G D,Fischer D A.Distortions of fluorescence yield X-ray absorption spectra due to sample thickness[J].Microchemical Journal,2002,71(2):281-286.
  • 6Schneider U,Pedroni E.Multiple coulomb scattering and spatial resolution in proton radiography[J].Medical Physics,1994,21(11):1657-1663.
  • 7Cunningham G S,Morris C L.The development of flash radiography[R].Los Alamos Science,2003.
  • 8King N S P,Ables E,Alrick K R,et al.An 800-MeV proton radiographic facility for dynamic experiments[J].Nuclear Instruments and Methods in physics research A,1999,424(1):84-91.
  • 9Kwan T J T,Mathews A R,Christenson P J,et al.Integrated system simulation in X-ray radiography[R].LA-UR-01-0071,2001.
  • 10Amann J F,Espinoza C J,Gomez J J,et al.High-energy test of proton radiography concepts[R].LA-UR-97-4721,1997.