摘要 Since the invention of Zernike phase contrast method in 1930,it has been widely used in optical microscopy and more recently in X-ray microscopy.Considering the image contrast is a mixture of absorption and phase information,we recently have proposed and demonstrated a method for quantitative phase retrieval in Zernike phase contrast X-ray microscopy.In this contribution,we analyze the performance of this method at different photon energies.Intensity images of PMMA samples are simulated at 2.5 keV and 6.2 keV,respectively,and phase retrieval is performed using the proposed method.The results demonstrate that the proposed phase retrieval method is applicable over a wide energy range.For weakly absorbing features,the optimal photon energy is 2.5 keV,from the point of view of image contrast and accuracy of phase retrieval.On the other hand,in the case of strong absorption objects,a higher photon energy is preferred to reduce the error of phase retrieval.These results can be used as guidelines to perform quantitative phase retrieval in Zernike phase contrast X-ray microscopy with the proposed method. Since the invention of Zernike phase contrast method in 1930,it has been widely used in optical microscopy and more recently in X-ray microscopy.Considering the image contrast is a mixture of absorption and phase information,we recently have proposed and demonstrated a method for quantitative phase retrieval in Zernike phase contrast X-ray microscopy.In this contribution,we analyze the performance of this method at different photon energies.Intensity images of PMMA samples are simulated at 2.5 keV and 6.2 keV,respectively,and phase retrieval is performed using the proposed method.The results demonstrate that the proposed phase retrieval method is applicable over a wide energy range.For weakly absorbing features,the optimal photon energy is 2.5 keV,from the point of view of image contrast and accuracy of phase retrieval.On the other hand,in the case of strong absorption objects,a higher photon energy is preferred to reduce the error of phase retrieval.These results can be used as guidelines to perform quantitative phase retrieval in Zernike phase contrast X-ray microscopy with the proposed method.
出处 《Chinese Physics C》 SCIE CAS CSCD 2016年第2期107-112,共6页 中国物理C(英文版)
基金 Supported by the State Key Project for Fundamental Research(2012CB825801) National Natural Science Foundation of China(11475170,11205157 and 11179004) Anhui Provincial Natural Science Foundation(1508085MA20)
关键词 X-ray microscopy Zernike phase contrast quantitative phase retrieval X-ray microscopy Zernike phase contrast quantitative phase retrieval
  • 相关文献

参考文献19

  • 1F. Zernike, Physica, 9 (10): 974-986 (1942).
  • 2G. Schmahl, D. Rudolph, P. Guttmann et al, Rev. Sci. In- strum., 66 (2): 1282-1286 (1995).
  • 3C. Holzner, M. Feser, S. Vogt et al, Nat. Phys., 6 (11): 883 887 (2010).
  • 4M. Stampanoni, R. Mokso, F. Marone et al, Phys. Rev. B, 81 (14): 140105 (2010).
  • 5D. Wang, N. Li, Z. Wang et al, J. Synchrotron Rad., 21 (5): 1175-1179 (2014).
  • 6M. Awaji, Y. Suzuki, A. Takeuchi et al, J. Synchrotron Rad., 9 (3): 125-127 (2002).
  • 7H. S. Youn and S. W. Jung, J. Microsc., 223 (1): 53-56 (2006).
  • 8A. Tkachuk, F. Duewer, H. Cui et al, Z. Kristallogr., 222 (11): 650-655 (2007).
  • 9Y. Liu, J. C. Andrews, J. Wang et al, Opt. Express, 19(2): 540 545 (2011).
  • 10Q. Yuan, K. Zhang, Y. Hong et al, J. Synchrotron Rad., 19 (6): 1021-1028 (2012).

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部