摘要 500 kV高温超导限流器技术是目前世界上电压等级最高的高温超导限流器技术,它应用在电网中可有效解决由于电网结构加强产生的主干电网短路电流水平过高问题,同时又不降低电网运行的可靠性和灵活性,但目前还没有一个成熟的500 kV高温超导限流器电气主接线方案。根据目前高温超导限流器技术和设备最新研究进展,提出了4种500 kV高温超导限流器接入系统的电气主接线方案,并通过可靠性、保护配置和造价等的综合比选提出推荐方案,该方案适用于超导限流器可靠性不高且严重故障后需要立即切除的设备发展现状,故障后需要立即切除的技术发展现状。 The state of art 500 kV high temperature superconducting fault current limiter operates at the highest voltage level. The use of 500 kV high temperature superconducting fault current limiter ean reduce short-circuit current in the system without reduction of reliability and flexibility. However, there is no well accepted main electrical connection for the limiter. Four different kinds of main connection schemes are discussed. Recommendation is made after comprehensive comparison on reliability, protection configuration and equipment cost. The recommended scheme is suitable for low reliability 500 kV high temperature superconducting fault current lirniter which must be removed immediately after failure occurrence.
出处 《中国电力》 CSCD 北大核心 2016年第2期96-101,共6页 Electric Power
关键词 500 KV 高温超导限流器 主动式限流 电气主接线 可靠性 保护配置 综合比选 500 kV high temperature superconducting fault current limiter active current limiter main connection reliability relay protection configuration comprehensive comparison
  • 相关文献

参考文献15

  • 1YE Lin, LIN Liangzhen, JUENGST KP. Application studies of superconducting fault current limiters in electric power systems[J]. IEEE Trans on Applied Superconductivity, 2002, 12(1): 900-903.
  • 2RAJU B P, PARTON K C, BARTRAM T C. A current limiting device using superconducting D.C. bias applications and prospects[J]. IEEE Trans on Power Apparatus & Systems, 1982, Pas-101(9): 3173-3177.
  • 3GYORE A, SEMPERGER S, FARKAS L, et al. Improvement of functionality and reliability by inductive HTS fault current limiter units [J]. IEEE Trans on Applied Superconductivity, 2005, 15(2):2086-2089.
  • 4SUGIMOTO S, KIDA Y, ARITA H, et al. Principle and characteristics of a fault current limiter with series compensation[J]. IEEE Trans on Power Delivery, 1996, 11(2): 846-847.
  • 5王付胜,刘小宁.饱和铁心型高温超导故障限流器数学模型的分析与参数设计[J].中国电机工程学报,2003,23(8):135-139. 被引量:53
  • 6LI Bin, LI Chao, GUO Fengrui, et al. Coordination of superconductive fault current limiters with zero-sequence current protection of transmission lines[J]. IEEE Trans on Applied Superconductivity, 2014, 24(5): 5602105.
  • 7LI Bin, LI Chao, GUO Fengrui, et al. Overcurrent protection coordination in a power distribution network with the active superconductive fault current limiter[J]. IEEE Trans on Applied Superconductivity, 2014, 24(5): 5602004.
  • 8马幼捷,王辉,陈岚,龚娟,周雪松,田密.新型桥式超导故障限流器的仿真研究[J].中国电力,2009,42(2):19-23. 被引量:2
  • 9周雪松,向龙瑞,马幼捷,徐晓宁.故障限流装置的发展和应用[J].电工技术学报,2004,19(11):1-7. 被引量:53
  • 10叶莺,肖立业.超导故障限流器的应用研究新进展[J].电力系统自动化,2005,29(13):92-96. 被引量:53

二级参考文献119

共引文献223

同被引文献26

引证文献5

二级引证文献3

相关作者