Implementation of a single quad MS detector in routine QC analysis of peptide drugs

Implementation of a single quad MS detector in routine QC analysis of peptide drugs
下载PDF
导出
摘要 A newly developed single quad mass spectrometry (MS) detector was coupled to a ultra-high perfor- mance liquid chromatography (UPLC) system and implemented in the routine quality control (QC) and impurity analysis of four therapeutic peptides, namely bleomycin sulfate, tyrothricin, vancomycin HCl and bacitracin, which were selected given their multi-component drug nature and their closely struc- turally related impurity profiles. The QC and impurity profiling results obtained using the ultra-high performance liquid chromatography ultraviolet/mass spectrometry (UPLC-UV/MS) detection system were analyzed against the results obtained using traditional high performance liquid chromatography- ultraviolet detection (HPLC-UV) methods derived from pharmacopoeial methods. In general, the used stationary phases of sub-2 μm particle (UPLC) technology resulted in lower limits of detection and higher resolution separations, which resulted in more detected impurities and shorter overall run times con- trasting the traditional HPLC columns. Moreover, online coupling with a single quad MS detector allowed direct peak identification of the main compounds as well as small impurities, hereby increasing the information content without the need of reference standards. A newly developed single quad mass spectrometry (MS) detector was coupled to a ultra-high perfor- mance liquid chromatography (UPLC) system and implemented in the routine quality control (QC) and impurity analysis of four therapeutic peptides, namely bleomycin sulfate, tyrothricin, vancomycin HCl and bacitracin, which were selected given their multi-component drug nature and their closely struc- turally related impurity profiles. The QC and impurity profiling results obtained using the ultra-high performance liquid chromatography ultraviolet/mass spectrometry (UPLC-UV/MS) detection system were analyzed against the results obtained using traditional high performance liquid chromatography- ultraviolet detection (HPLC-UV) methods derived from pharmacopoeial methods. In general, the used stationary phases of sub-2 μm particle (UPLC) technology resulted in lower limits of detection and higher resolution separations, which resulted in more detected impurities and shorter overall run times con- trasting the traditional HPLC columns. Moreover, online coupling with a single quad MS detector allowed direct peak identification of the main compounds as well as small impurities, hereby increasing the information content without the need of reference standards.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2016年第1期24-31,共8页 药物分析学报(英文版)
基金 funded by PhD grants of‘Institute for the Promotion of Innovation through Science and Technology in Flanders(IWT-Vlaanderen)’(No.101529(MD)and 121512(BG))
关键词 Quality control PEPTIDE Impurity profiling Single quad MS detector Quality control Peptide Impurity profiling Single quad MS detector
  • 相关文献

参考文献37

  • 1R. Aebersold, M. Mann, Mass spectrometry-based proteomics, Nature 422 (2003) 198-207.
  • 2A. Pandey, M. Mann, Proteomics to study genes and genomes, Nature 405 (2000) 837-846.
  • 3B. Domon, IL Aebersold, Mass spectrometry and protein analysis, Science 312 (2006) 212-217.
  • 4S.-E. Ong, M. Mann, Mass spectrometry-based proteomics turns quantitative, Nat. Chem. Biol. I (2005) 252-262.
  • 5X. Zhang, D. Wei, Y. Yap, et aI., Mass spectrometry-based "omics" technologies in cancer diagnostics, Mass Spectrum. Rev. 26 (2007) 403-431.
  • 6M.S. Lee, E.H. Kerns, LC/MS applications in drug development, Mass Spectrum. Rev. 18 (1999) 187-279.
  • 7R. Kostiainen, T. Kotiaho, T. Kuuranne, et al., Liquid chromatography/atmo- spheric pressure ionization-mass spectrometry in drug metabolism studies, J. Mass Spectrom. 38 (2003) 357-372.
  • 8W. Xu. N.E. Manicke, G.IL Cooks, et al., Miniaturization of mass spectrometry analysis systems, J. Lab. Autom. 15 (2010) 433-439.
  • 9S.E. Hamilton, F. Mattrey, X. Bu, eta]., Use of miniature mass spectrometer to support pharmaceutical process chemistry, Org. Process Res. Dev. 18 (2014) 103-108.
  • 10X. Bu, J. Yang, X. Gong, et al., Evaluation of compact mass spectrometer for routine support of pharmaceutical chemistry, J. Pharm. Biomed. Anal. 94 (2014) 139-144.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部