期刊文献+

闭合复位与切开复位治疗老年桡骨远端骨折的疗效及对腕关节功能的影响 被引量:45

下载PDF
导出
摘要 目的探讨闭合复位与切开复位治疗老年桡骨远端骨折的临床效果及对腕关节功能的影响。方法选择老年桡骨远端骨折患者84例,随机分为研究组和对照组各42例,对照组行闭合复位术,研究组行切开复位术,观察两组患者术后疗效及腕关节功能恢复情况。结果研究组术后尺偏角、掌倾角以及桡骨长度均优于对照组(P<0.05);研究组腕关节功能恢复优良率明显高于对照组(P<0.05)。结论对老年不稳定性桡骨远端骨折患者,采用切开复位内固定治疗能恢复桡骨长度,促进腕关节功能恢复,获得理想的复位质量和疗效。
出处 《中国老年学杂志》 CAS CSCD 北大核心 2016年第4期915-916,共2页 Chinese Journal of Gerontology
  • 相关文献

参考文献8

  • 1Wagner DW,Lindsey DP,Beaupre GS.Replicating a colles fracture in an excised radius:revisiting testing protocols[J].J Biomech,2012;45(6):997-1002.
  • 2Zoetsch S,Kraus T,Weinberg AM,et al.Fracture of the ulnar styloid process negatively influences the outcome of paediatric fractures of the distal radius[J].Acta Orthop Belg,2013;79(1):48-53.
  • 3Kim JK,Koh YD,Do NH.Should an ulnar styloid fracture be fixed following volar plate of fixtion of a distal radial fracture[J]?J Bone Joint Surg(Am),2010;92(1):1-6.
  • 4Kramer S,Meyer H,O'Loughlin PF,et al.The incidence of ulnocarpal complaints after distal radial fracture in relation to the fracture of the ulnar styloid[J].J Hand Surg Eur,2013;38(7):710-7.
  • 5李书振,陈跃平,林宗汉,丰哲,赵劲民,苏伟.切开复位与闭合复位治疗老年桡骨远端骨折的对比研究[J].中国修复重建外科杂志,2010,24(4):438-442. 被引量:23
  • 6邓雪峰,周丽英,陈杰明,黄定根,夏翠兰.锁定加压接骨板固定治疗桡骨远端骨折[J].中国现代手术学杂志,2012,16(5):356-358. 被引量:5
  • 7张峰,牒军,曹斌,李展奇,陈明伟.中西医结合治疗桡骨远端骨折的临床分析[J].现代生物医学进展,2015,15(17):3294-3296. 被引量:24
  • 8Marshall T,Momaya A,Eberhardt A,et al.Biomechanical comparison of volar fixed-angle locking plates for AO C3distal radius fractures:titanium versus stainless steel with compression[J].J Hand Surg Am,2015;40(10):2032-8.

二级参考文献30

  • 1唐佩福,黄鹏,崔庚,梁雨田,陶笙,郭义柱,张群,梁向党,杨明玉,王岩.掌侧锁定加压钢板治疗桡骨远端背侧不稳定性骨折[J].中国矫形外科杂志,2006,14(16):1207-1209. 被引量:23
  • 2Hanel DP, Jones MD, Trurable TE. Wrist fractures [ J]. OrthopClin North Am, 2002,33(1) :35-57, vii.
  • 3Monda MK,Ellis A,Karmani S. Late rupture of flexor pollicis lon-gus tendon 10 years after volar buttress plate fixation of a distal ra-dius fracture : a case report [ J ]. Acta Orthop Belg, 2010 ,76(4):549-551.
  • 4Dienst M, Woz^ek GE, Seligson D. Dynamic external fixation fordistal radius fractures[ J]. Clin Orthop Relat Res, 1997, (338):160-171.
  • 5Moroni A, Faldini C, Marchetti S, et al. Improvement of thebone-pin interface strength in osteoporotic bone with use ofhydroxyapatite-coated tapered extemal-fixation pins. A prospec-tive ,randomized clinical study of wrist fractures[ J]. J Bone JointSurg Am, 2001,83-A(5) :717-721.
  • 6Ring D,Prommersberger K, Jupiter JB. Combined dorsal andvolar plate fixation of complex fractures of the distal part of theradius[J]. J Bone Joint Surg Am, 2004,86-A(8) : 1646-1652.
  • 7Suganuma S, Tada K, Tsuchiya H. Reducing the risk of flexor pollicis longus tendon rupture atter volar plate fixation for distal radius fractures: validation of the tendon irritation test [J]. European journal of orthopaedic surgery & tranmatology, 2014, 24(8): 1425-1429.
  • 8Tarallo L, Mugnai R, Adani R. Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate [J]. Journal of orthopaedics and trattmatology, 2014, 15(4): 285-290.
  • 9Tarallo L, Mugnai R, Adani R. A new volar plate made of carbon-fiber-reinforced polyetheretherketon for distal radius fracture: analysis of 40 cases [J]. Joumal of orthopaedics and traumatology, 2014, 15(4): 277-283.
  • 10Wichlas F, Haas NP, Disch A. Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distalradius fractures [J]. Journal of orthopaedics and traumatology, 2014, 15(4): 259-264.

共引文献49

同被引文献303

引证文献45

二级引证文献365

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部