期刊文献+

Optimization Design and Experiment of the Radio Frequency Transmission Utilized in Video Capsule Endoscope

Optimization Design and Experiment of the Radio Frequency Transmission Utilized in Video Capsule Endoscope
原文传递
导出
摘要 In view of fuzzy and unstable images received in video capsule endoscopy, and the poor communication effect, an improved radio frequency(RF) transmission circuit module with low power consumption and helix antenna is designed to improve the performance of video transmission and to extend the working time of the capsule. Simulation and analysis of the circuits and antenna with HFSS12 and ADS2011 software are highlighted.Video capsule endoscope prototypes are made and evaluated to verify the feasibility of the proposed design. In vitro tests and animal experiments show that the results of the antenna tests basically meet the simulation, and the power consumption of RF circuit is 15.9 mV. The video capsule endoscope works well with the receiver with multiple receiving antennas, and the working time is more than 9 h. It can realize the wireless transmission of the video data, and images received are clear and stable in comparison with the previous designs. In view of fuzzy and unstable images received in video capsule endoscopy, and the poor communication effect, an improved radio frequency (RF) transmission circuit module with low power consumption and helix antenna is designed to improve the performance of video transmission and to extend the working time of the capsule. Simulation and analysis of the circuits and antenna with HFSS12 and ADS2011 software are highlighted. Video capsule endoscope prototypes are made and evaluated to verify the feasibility of the proposed design. In vitro tests and animal experiments show that the results of the antenna tests basically meet the simulation, and the power consumption of RF circuit is 15.9 inV. The video capsule endoscope works well with the receiver with multiple receiving antennas, and the working time is more than 9 h. It can realize the wireless transmission of the video data, and images received are clear and stable in comparison with the previous designs.
出处 《Journal of Shanghai Jiaotong university(Science)》 EI 2016年第1期1-6,共6页 上海交通大学学报(英文版)
基金 the National Natural Science Foundation of China(No.31170968) the Shanghai Science Committee Foundation(No.09DZ1907400)
关键词 video capsule endoscopy radio frequency(RF) transmission circuit helix antenna animal experiment video capsule endoscopy, radio frequency (RF) transmission circuit, helix antenna, animal experiment
  • 相关文献

参考文献9

二级参考文献73

共引文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部