摘要
介绍了M701F燃机燃气蒸汽联合循环机组余热锅炉运行过程中第一模块容易爆管的问题,详细介绍了余热锅炉第一模块爆管情况、原因分析及解决办法,以期为相关工作提供借鉴。
This paper introduced that the tube of the first module is easy to explode in the process of the waste heat boiler operation of gas-steam combined cycle unit of MTO1F gas turbine, and provided detailed information on tube explosion, reason analysis and solution of the first module in waste heat boiler in order to provide reference for the related work.
出处
《能源与节能》
2016年第2期28-29,31,共3页
Energy and Energy Conservation
关键词
燃气蒸汽联合循环
余热锅炉
第一模块
爆管
原因
对策
gas-steam combined cycle
waste heat boiler
the first module
tube explosion
reason