ICP-OES测定机顶盒电源线中铅的不确定度评定

Uncertainty evaluation of ICP—OES analysis method for lead in power cord of TV set-top box
下载PDF
导出
摘要 运用JJF1059.1—2012《测量不确定度评价与表示》中的分析方法,对ICP-OES测定电视机顶盒电源线中铅含量方法所建立的定量数学模型进行了不确定度评定。包括分析实验过程中的不确定度来源,并对不确定度的分量进行了评定和量化,计算了合成不确定度和扩展不确定度。结果表明,电视机顶盒的电源线的铅含量W=48.03 mg/kg,其中扩展不确定度为3.2 mg/kg,在置信概率为95%时,铅的含量可表示为(48.03±3.2)mg/kg。 The analysis method in JJF1059.1--2012 〈 Evaluation and Expression of Uncertainty in Measurement 〉 is used for ana- lyzing the mathematical model quantitative of a method which is built to determinate lead content in the power cord of TV set-top box by ICP-OES. The uncertainty sources are analyzed. Each component of uncertainty is evaluated and quantified and then the combined uncertainty and the expanded uncertainty are calculated. The results show that the expanded uncertainty is 3.2 mg/kg as the content of lead in the power cord of TV set-top box is 48.03 mg,/kg. When the confidence probability is 95% , the content of lead can he expressed as (48.03±3.2) mg/kg.
出处 《电视技术》 北大核心 2016年第2期146-149,共4页 Video Engineering
关键词 不确定度 ICP—OES 电视机顶盒 Uncertainty ICP-OES lead TV set-top box
  • 相关文献

参考文献4

  • 1RoHS:2011/65/EU,关于在电气电子设备中限制使用某些有害物质指令[S].2011.
  • 2CNAS-CL10:2012检测和校准实验室能力认可准则在化学检测领域的应用说明[S].2012.
  • 3JJF1059,1-2012测量不确定度评定与表示[S],2012.
  • 4刘化玲,牛丽川,黄小亚,张谷一.ICP-OES测定铅汞镉的参数优化[J].电视技术,2012,36(12):90-91. 被引量:4

二级参考文献3

  • 1RoHS:2002/95/EC,关于在电气电子设备巾限制使用某些有害物质指令[S/OL].[2011-10-01].http://www.cqc.com.cn/chinese,uIlnles,2007/5/200751810278429.pdf.
  • 2GB/T26572--2011,电子电气产品中限用物质的限量要求[S].2011.
  • 3国家广播电视产品质量监督检验中心,巾国电子科技集团公司第三研究所,天津大学电子信息工程学院.数字电视原理与检测技术[M].北京:人民邮电出版社,2011:564-565.