期刊文献+

光学相干断层成像技术在定窑瓷器检测中的应用 被引量:8

Non-Invasive Investigation of Microstructure of Ding Kiln Porcelain with Optical Coherence Tomography
原文传递
导出
摘要 光学相干断层成像(OCT)是基于低相干光干涉仪,可对物体进行断层成像的技术。OCT系统的无损检测和图像高速采集特征使其适于对历史文物进行成像检测,并提供文物表面下的结构信息。对OCT技术原理进行了阐述,并采用OCT系统对来自北宋的定窑瓷器进行无损检测及断层图像的采集。通过定窑瓷器的OCT断层图像,可观察到定窑瓷器表层釉质和胎体层,层状结构以及不同结构的界面也清晰可见。通过对OCT断层图像的分析,可获知瓷器表面的施釉情况及釉层特点,釉层和胎体的风化特征及其中气泡及晶体颗粒的分布、OCT图像对瓷器的穿透深度等信息。同时可分析釉层和胎体表面工艺以及二次修补的信息。 Optical coherence tomography (OCT) is a non-destructive subsurface tomography system based on low coherence interferometry. Non-invasive nature and high speed of acquisition of OCT make it possible to image relic and provide subsurface morphology visualization. Porcelain from Ding kiln of Northern Song Dynasty is scanned and imaged to visualize the subsurface morphology of the surface glaze and core. Layer structures and interfaces can be visualized clearly from OCT images. The characteristics of the thickness of the glaze layer, bubbles and crystal particles in glaze, the penetration depth of OCT in porcelain are analyzed.
出处 《中国激光》 EI CAS CSCD 北大核心 2016年第2期189-195,共7页 Chinese Journal of Lasers
基金 国家重点科技支撑项目(2015BAI01B06) 陕西省科技统筹创新计划(2013KTCQ03-09)
关键词 成像系统 光学相干断层成像 瓷器 釉层 胎体 imaging systems optical coherence tomography porcelain core glaze
  • 相关文献

参考文献25

  • 1H Liang, M Cid, R Cucu, et al.. En-face optical coherence tomography-a novel application of non-invasive imaging to art conservation [J]. Opt Express, 2005, 13(16): 6133-6144.
  • 2Defang J, Paijun D, Yuzhi K, et al.. Holographic non-destructive testing for cultural relics[C]. SPIE, 1983, 370: 259-265.
  • 3Schreiner M, Frtihmann B, Jembrih-Simburger D, et al.. X-rays in art and archaeology: an overview[J]. Powder Diffraction, 2004, 19(1): 3-11.
  • 4Verhoew~n G. Imaging the invisible using modified digital still cameras for straightforward and low-cost archaeological near-infraredphotography[J]. Journal of Archaeological Science, 2008, 35(12): 3087-3100.
  • 5Verhoeven G J, Smet P F, Poelman D, et al.. Spectral characterization of a digital still camera's NIR modification to enhance archaeological observation[J]. IEEE Trans Geoscience and Remote Sensing, 2009, 47(10): 3456-3468.
  • 6Evans A A, Donahue R E. Laser scanning confoeal microscopy: A potential technique for the study of lithic microwear[J]. Journal of Archaeological Science, 2008, 35(8): 2223-2230.
  • 7Derndarsky M, Oeklind G. Some preliminary observations on subsurface damage on experimental and archaeological quartz tools using CLSM and dye[J]. Journal of Archaeological Science, 2001, 28(11): 1149-1158.
  • 8Hunt C O, Rushworth G, Dykes A P. UV-fluorescence microscopy and the coherence of pollen assemblages in environmental archaeology and Quaternary geology[J]. Journal of Archaeological Science, 2007, 34(4): 562-571.
  • 9Creagh D C, Bradley D A. Radiation in Art and Archeometry[M]. Amsterdam: Elsevier, 2000.
  • 10杨珊珊,朱锐,米磊,曹一挥,李青云.光学相干层析成像技术对壁画的检测研究[J].光学学报,2015,35(5):147-152. 被引量:13

二级参考文献78

  • 1孙兵,顾成权,方云,王金华,乌布力.买买提.艾里,王琦,彭啸江.应用超声波检测地杖层空腔区域[J].工程地球物理学报,2004,1(6):489-493. 被引量:2
  • 2曾楠,何永红,马辉,王淑霞.应用于珍珠检测的光学相干层析技术[J].中国激光,2007,34(8):1140-1145. 被引量:25
  • 3J G Fujimoto, W Drexler. Introduction to Optical Coherence tomography[M]. W Drexler, J G Fujimoto, Eds., Optical Coherence Tomography Technology and Applications. New York: Springer, 2008. 1-45.
  • 4D Huang, E A Swanson, C P Lin, et al. Optical coherence tomography[J]. Science, 1991, 254(5035): 1178-1181.
  • 5A F Fercher, C K Hitzenberger, G Kamp, et al. Measurement of intraocular distances by backscattering spectral interferometry [J]. Opt Commun, 1995, 117(1 2): 43- 48.
  • 6M Wojtkowski, R Leitgeb, A Kowalczyk, eta&. In vivo human retinal imaging by Fourier domain optical coherence tomography [J]. J Biomedical Opt, 2002, 7(3):457-463.
  • 7R Leitgeb, C K Hitzenberger, A F Fercher. Performance of Fourier domain versus time domain optical coherence tomography [J]. Opt Express, 2003, 11(8): 889-894.
  • 8B E Bouma, G J Tearney. Optical Sources [M]. B E Bouma, G J Tearney, Eds. , Handbook of Optical Coherence Tomography. New York: Marcel Dekker, 2002. 67-97.
  • 9A F Fereher, C K Hitzenberger, M Sticker, et al. Numerical dispersion compensation for partial coherence interferometry and optical coherence tomography [J]. Opt Express, 2001, 9 (12) : 610-615.
  • 10C K Hitzenberger, A Dispersion effects in Baumgartner, W Drexler, et al. partial coherence interferometry implications for intraocular ranging [J]. J Biomedical Opt, 1999, 4(1): 144-151.

共引文献53

同被引文献119

引证文献8

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部