期刊文献+

新型便携式肌力测定仪测量下肢肌肉的信度研究 被引量:6

下载PDF
导出
摘要 目的:测试OE-210肌力测定仪在正常青年人群中的信度。方法:正常青年人42名,由2位治疗师分别使用OE-210肌力测定仪进行下肢股四头肌和腘绳肌的肌力测定,其中1位治疗师在3d后重复测试1次。计算组内相关系数(ICC),以及相应测量标准误(SEM)和最小可测得差异值(MDD95)。结果:同一测试者重复测量股四头肌、腘绳肌肌力的信度为中等至优秀(ICC=0.74~0.92);不同测试者间股四头肌、腘绳肌肌力测量的信度均为好(ICC=0.80~0.88)。股四头肌的SEM和MDD95值分别为2.50~2.79和6.92~7.73。腘绳肌的SEM和MDD95值分别为1.86~2.43和5.16~6.74。结论:OE-210肌力测定仪测试下肢股四头肌、腘绳肌的信度良好。
出处 《中国康复》 2016年第1期74-75,共2页 Chinese Journal of Rehabilitation
基金 广东省医学科研基金(A2015255) 广东省工伤康复医院院内课题重点项目(2015B002_A)
  • 相关文献

参考文献7

  • 1段亚景,王宁华.握力测量的研究进展[J].中国康复理论与实践,2009,15(10):948-951. 被引量:37
  • 2Pormey LG, Watkins MP. Foundations of Clinical Research: Ap- plications to Practice[M]. 3rd. Upper Saddle River, NJ: Prentice Hall Health; 2009, 585-618.
  • 3Koski L, Lin JC, Wu AD, et al. Reliability of intracortical and cortieomotor excitability estimates obtained from the upper ex- tremities in chronic stroke[J]. Neurosci Res, 2007, 58(1): 19- 31.
  • 4Thorborg K, Bandholm T, Schick M, et al. Hip strength assess- ment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength[J]. Scand J Med Sci Sports, 2013, 23(4): 487 -493.
  • 5Ieiri A, Tushima E, Ishida K, et al. Reliability of measurements of hip abduction strength obtained with a hand held dynamometer [J]. Physiother TheoryPract, 2015, 31(2):146-152.
  • 6Katoh M, Isozaki K. Reliability of Isometric Knee Extension Muscle Strength Measurements of Healthy Elderly Subjects Made with a Hand-held Dynamometer and a Belt[J]. J Phys Ther Sci. 2014, 26(12) :1855-1859.
  • 7Yamasaki H, Katoh M, Kajiwara K. The limit of manual fixing in knee extension muscle strength measurements[J]. Sogo Reha- bil, 2007, 35: 1369-1371.

二级参考文献39

  • 1王刚,瓮长水,王军.握力检查在神经根型颈椎病疗效评价中的应用[J].中国康复医学杂志,2007,22(3):256-257. 被引量:13
  • 2Hunter JM, Mackin EJ, Callahan AD. Rehabilitation of the Hand: Surgery and Therapy[M]. 4th ed. St. Louis: Mosby, 1995:185--214, 1345--1350, 1839--1901.
  • 3Bechtol CO. Grip Test: lhe use of a dynamometer with adjustable handle spacings[J]. Bone Joint Surg Am, 1954, 36:820--824.
  • 4Innes E. Handgrip strength testing: a review of the literature[J]. Aust Occup Ther, 1999, 46: 120--140.
  • 5Shechtman O, Davenport R, Malcolm M, et al. Reliability and validity of the BTE Primus grip tool[J]. J Hand Ther, 2003, 16:36--42.
  • 6Shechtman O. Reliability and validity of the DynEx Dynat mometer[J]. J Hand Ther, 2005, 18: 339--347.
  • 7Watanabe T, Owashi K. The short-term reliability of grip strength measurement and the effects of posture and grip span[J]. J Hand Surg, 2005, 30A: 603--609.
  • 8Fess EE. Gripstrength/CasanovaJS, ed. ClinicalAssessmentRecommendations[M]. 2nd ed. Chicago: American Society of Hand Therapists,1992:41--45.
  • 9Myung-Chul Jung,M. Susan Hallbeck Quantification of the effects of instruction type, verbal encouragement, and visual feedback on static and peak handgrip strength[J]. Int J Industrial Ergonomics, 2004, 34:367-374.
  • 10Mathiowetz V. Effect of three trials on grip and pinch strength measurement[J]. J Hand Ther, 1990, 3: 195-- 198.

共引文献36

同被引文献52

引证文献6