摘要 变压器油中存在腐蚀性硫和铜离子会严重威胁变压器的安全稳定运行。针对腐蚀性硫和铜离子综合治理这一技术难题,采用吸附法对变压器油进行脱除处理。结果表明:经过84 h吸附处理,油中铜离子含量从1.2 mg/kg降至0.2 mg/kg,介质损耗因数从1.57%降至0.057%,体积电阻率从3.6×10^(10)Ω·m升至1.96×10^(12)Ω·m,总硫含量从550.1 mg/kg降至380.8 mg/kg,腐蚀性硫含量从51.6 mg/L降至18.1 mg/L。绕组绝缘电阻提高约3倍,吸收比恢复正常。处理过程对抗氧剂T501含量、水分、酸值、界面张力和击穿电压没有不良影响。 Corrosive sulfur and copper ion often exist in transformer oils. It is extremely dangerous to the safety and Stability operation of transformers. In view of this technical problem, we used an effective adsorbent to remove the corrosive sulfur and copper ion. The results show that after adsorption treatment for 84 h, the copper ion decreases from 1.2 mg/kg to 0.2 mg/kg, the dielectric loss factor decreases from 1.57% to 0.057%, the volume resistivity increases from 3.6×10^10Ω·m to 1.96×10^11Ω·m, the total sulfur decreases from 550.1 mg/kg to 380.8 mg/kg, and the corrosive sulfur decreases from 51.6 mg/L to 18.1 mg/L. The insulation resistance of transformer winding increases about three times, and the absorp- tion ratio return to normal. Moreover, the treatment process has no harmful effect to the antioxidant T501 content, water, interfacial tension acid value, and breakdown voltage.
出处 《绝缘材料》 CAS 北大核心 2016年第2期70-74,共5页 Insulating Materials
基金 国网湖南省电力公司科研基金(5216A01300K0)
关键词 变压器油 铜离子 腐蚀性硫 绕组绝缘电阻 transformer oil copper ion corrosive sulfur winding insulation resistance
  • 相关文献

参考文献14

  • 1Wiklund P, Levin M, Pahlavanpour B. Copper Dissolution and Metal Passivatorsin Insulating Oil[J]. IEEE Electrical Insulation Magazine,2007,23(4):6-14.
  • 2Tang C, Yang L J, Feng Y, et al. Study on the Influence of Copper Ion on Aging Rate of Transformer Oil-paper Insulation[C]//2008 International Conference on High Voltage Engineering and Application,Chongqing,China,2008:570-573.
  • 3Lewand L R. The Role of Corrosive Sulfur in Transformers and Transformer Oils: 70th International Conference of Doble Clients[C]//MA Insulating Materials Session, Boston, 2002.
  • 4任双赞,钟力生,曹晓珑.矿物绝缘油中腐蚀性硫问题研究[J].绝缘材料,2010,43(3):69-73. 被引量:24
  • 5Lewand L R. The Negative Effects of Corrosive Sulfur on Transformer Components[J]. Doble Engineering Company/ NETA World,2004:1-4.
  • 6钱艺华,胡红红,姚唯建.腐蚀性硫导致变压器故障的综合分析及处理[J].变压器,2008,45(1):28-30. 被引量:43
  • 7陆志浩,彭伟,傅晨钊.大型变压器绝缘油中硫腐蚀的危害及防护对策研究[J].华东电力,2008,36(11):39-42. 被引量:8
  • 8Brown W G. Review of Results of Corrosive Sulfur Testing Using Doblc Engineering's Amended ASTM Method D1275 [C]//Proceedings of the 73nd International Conference of Doble Clients, Boston,MA,2006.
  • 9CIGRE WG A2-32. Copper Sulphide in Transformer Insulation, Final Report[R]. CIGRE WG A2-32,Brochure 378,2009.
  • 10Scatiggio F, Tumiatti V, Maina R, et al. Corrosive Sulfur Induced Failures in Oil-filled Electrical Power Transformers and Shunt Reactors[J]. IEEE Transactions on Power Delivery,2009,24(3 ): 1240-1248.

二级参考文献39

  • 1ABB公司研究报告.ABB评论,2004,(3).
  • 2L R Lewand. The Role of Corrosive Sulfur in Transformers And Transformer Oil[ J ]. Doble Engineering Company, USA.
  • 3M Dahlund. Copper SuLphide in Transformer Insulation-status report [ J ]. CIGRE WG A2-32, 2007, (9).
  • 4Dealing with Corrosive Sulfur in Insulating Oils. EPR1 of USA, 2006, (5).
  • 5L Lewand. Investigating Copper Sulfide Contamination in a Failed Large GSU Transformer[ C]. Proceedings of the Seventy-second Annual Doble Conference of Doble Clients. MA, Insulating Materials Session, 2005.
  • 6Rocha A H.Faults in 500kV Shunt Reactors Caused by Corrosive Sulfur in the Insulation Oil:Proceeding of International Conference of Doble Clients[C].Boston:[Publisher Unknown] ,2001.
  • 7Bengtsson C,Dahlund M,Hajek J,et al.Oil Corrosion and Conduting Cu2S Deposition in Power Transformer Windings:CIGRE Main Session[C].Paris,2006.
  • 8Lewand L R.The Role of Corrosive Sulfur in Transformers and Transformer Oils:70th International Conference of Doble Clients[C].Boston,2003.
  • 9Hajek J,Bennstam G,Dahlund H,et al.Quality of Oil Makes the Difference,ABB Discovers the Solution to Transformer Breakdowns[J].ABB Review,2004:61-63.
  • 10Tumiatti V,Maina R,Scatiggio F,et al.Corrosive Sulfur in Mineral Oils:Its Detection and Correlated Transformer Failures[J].IEEE International Symposium on Electrical Insulation,2006,7:400-402.

共引文献62

同被引文献67

引证文献8

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部