摘要
运用24完全析因实验设计,研究4种工艺参数因子(氧化剂H2O2用量、催化剂FeSO4用量、pH和反应时间)共同作用对芬顿氧化法降解有机废水的影响规律,利用固定效应模型估算各因子主效应和高阶交互效应对COD去除率的贡献。
Using 24 full factorial experimental design, the influence law of four process parameters (oxidant H2O2 dosage, catalyst FeSO4 dosage, pH and reaction time) interaction on Fenton oxidation degradation of organic wastewater was studied, using fixed effect model, to estimate the contribution of the main effect of each factor and high order in- teraction effect on the removal rate of COD was estimated.