期刊文献+

可调控屈光度人工晶状体研究新进展

Latest research progress of adjustable intraocular lens
下载PDF
导出
摘要 白内障术后人工晶状体(intraocular lens,IOL)屈光度数误差是白内障手术医生面临的重要临床问题,严重影响患者的术后视觉质量及手术满意度。可调控屈光度人工晶状体(adjustable IOL)的提出为白内障医生解决这一问题提供了新的途径。本文拟从可调控屈光度IOL的概念、临床意义及几种可调控屈光度IOL的设计及研究等方面进行介绍。可调控屈光度IOL将会给白内障手术带来新的技术革新。 Despite the many advances in cataract surgery,incorrect intraocular lens(IOL) power remains a significant clinical problem which seriously affects the postoperative visual quality and satisfaction.Adjustable intraocular lens can be adjusted to provide a new way to solve this problem.The general concepts and clinical significances of adjustable IOL,as well as the designs and studies of several kinds of adjustable IOL,are described in this review.Adjustable IOL will give a new technological innovation to the cataract surgery to improve outcomes and increase expectations.
出处 《国际眼科杂志》 CAS 2016年第3期455-457,共3页 International Eye Science
基金 辽宁省科技计划重点项目(No.2012225012)~~
关键词 白内障 可调控屈光度人工晶状体 屈光度数误差 cataract adjustable intraocular lens incorrect intraocular lens power
  • 相关文献

参考文献19

  • 1Ford J,Werner L,Mamalis N. Adjustable intraocular lens power technology. J Cataract Refract Surg,2014;40(7):1205-1223.
  • 2Jin GJC,Crandall AS,Jones JJ. Intraocular lens exchange due to incorrect lens power. Ophthalmology,2007;114(3):417-424.
  • 3滕贺,张红.人工晶状体置换术的临床观察[J].中国实用眼科杂志,2012,30(7):840-843. 被引量:4
  • 4赵姝芝,蔡可丽.儿童白内障手术人工晶状体度数计算准确性分析[J].中国实用眼科杂志,2011,29(8):847-851. 被引量:4
  • 5Werblin TP. Multicomponent intraocular lens. J Cataract Refract Surg,1996;12(1):187-189.
  • 6Partaliou DM,Grentzelos MA,Pallikaris IG. Multicomponent intraocular lens implantation:two-year follow-up. J Cataract Refract Surg,2013;39(4):578-584.
  • 7Jahn CE,Jahn MA,Kreiner CF,et al. Intraocular lens with reversibly adjustable optic power; pilot study of concept and safety. J Cataract Refract Surg,2003;29(9):1795-1799.
  • 8Jahn CE,Strotmann H. Investigation of the safety of an intraocular lens with adjustable optical power:the Acri. Tec AR-1PC/IOL. Ophthalmologica,2005;219(6):362-365.
  • 9Jahn CE,Sch?pfer DC. Cataract surgery with implantation of a mechanically and reversibly adjustable intraocular lens:*Acri.Tec AR-1 posterior chamber intraocular lens. Arch Ophthalmol,2007;125(7):936-939.
  • 10Matthews MW,Eggleston HC,Pekarek SD,et al. Magnetically adjustable intraocular lens. J Cataract Refract Surg,2003;29(11):2211-2216.

二级参考文献30

  • 1王文清,贾丽丽,陆斌,方健,陈颖.囊袋内人工晶状体重度移位或脱位的原因分析及处理[J].中华眼科杂志,2006,42(5):396-399. 被引量:6
  • 2陈小,叶剑,陈春林.后房型人工晶状体脱位的临床分析[J].中国实用眼科杂志,2006,24(11):1155-1157. 被引量:5
  • 3Wirth MG,Russel-Eggitt IM,Craig JE,et al. Aetiology of congenital and pediatric cataract in an Australian population [J]. Br J Ophthalmol,2002,g6 : 782-756.
  • 4Johan Z,Paul BM,Abdulaziz A,et al. Pediatric intraocular lens implantation: surgical results and complications in more than 300 patients [J]. Ophthalmology, 1998,105:112-119.
  • 5Torsten Schlote, Martin Kriegerowsk,Thomas Bende,et al. Mesopic vision in myopia corrected by photorefractive keratectomy,soft contact lenses,and spectacles [J].Journal of Cataract and Re- fractive Surgery, 1997,23 : 618.
  • 6Collenbrander MC. Calculation of an iris clip lens for distance vision [J]. Br J Ophthalmol,1973,57:735-740.
  • 7Binkhorst RD. The optical design of intraocular lens implants [J]. Ophthalmic Surg, 1975,6:17-31.
  • 8Sanders D, Retzlaff J,Kraft M,et al. Comparison accuracy of the Binkhorst,Colenbrander and SRK implant power prediction formulas [J]. J Am Intraocular Implant Soc,1981,7:337-340.
  • 9Andreo LK,Wilson ME,Saunders RA. Predictive value of regression and theoretical IOL formulas in. pediatric intraocular lens implantation [J]. J Pediatr Ophthalmol Strabismus,1997,34:240-3.
  • 10Tromans C,Haigh P M,Biswas S,et al. Accuracy of intraocular lens power calculation in paediatric cataract surgery [J]. Br J Ophthalmol,2001,85:939 - 941.

共引文献6