基于微电子阻抗技术实时细胞监测系统在细胞凋亡检测时点选择中的应用 被引量:3

Application of the Real-time Cell Analysis System in the Detection of Apoptosis
下载PDF
导出
摘要 目的探讨基于微电子阻抗技术的实时细胞监测系统用于确定细胞凋亡最佳检测时间点。方法应用顺铂诱导胶质瘤细胞U251凋亡,使用实时细胞监测系统连续74 h监测不同药物浓度作用于U251后细胞指数的动态变化,根据药物作用时间与细胞指数关系曲线确定凋亡最佳检测时间点,采用流式细胞仪分析细胞凋亡率。结果通过实时监测发现,2.5μg/m L、5μg/m L、10μg/m L顺铂分别在作用49 h、60 h和74 h,U251细胞指数值达到最低;在这些时间点,流式细胞仪检测细胞凋亡率分别达到高峰(15.6±1.4)%,(34.2±7.6)%,(63.9±4.6)%。结论应用实时细胞监测系统可进行细胞凋亡最佳检测时间点的辅助判断。 Objective To explore the optimal test time of real-time cell analysis system( RTCA) for apoptosis detection. Methods Real-time cell analyzer was utilized to continuously monitor and record the U251 dynamic changes induced by cisplatin. The appropriate test time for apoptosis was determined according to the curves of time vs cell index. Flow cytometer was used to evaluate the apoptosis of U251. Results RTCA data revealed that in 2. 5μg / m L,5μg / m L and 10μg / m L cisplastin treated groups,U251 cell index reduced to the lowest at the different time points,namely,49 h,60 h and 74 h,respectively. And at that time,the highest percentage of apoptotic cells of( 15. 6 ± 1. 4) %,( 34. 2 ± 7. 6) % and( 63. 9 ± 4. 6) % were found respectively. Conclusion RTCA could be very helpful in the determination of apoptosis detection time.
出处 《标记免疫分析与临床》 CAS 2016年第2期197-201,共5页 Labeled Immunoassays and Clinical Medicine
基金 首都医科大学附属北京天坛医院青年科研基金(2013年度) 脑肿瘤北京市重点实验室2014年开放课题(2014NZLY01) 北京市自然科学基金(7132094) 国家自然科学基金(81572474)
关键词 实时系统 凋亡检测 最佳检测 Real-time system Apoptosis detection Optimal test time
  • 相关文献

参考文献14

  • 1Elmore S. Apoptosis: a review of programmed cell death. Toxicol Pathol, 2007, 35(4):495-516.
  • 2Thompson C B. Apoptosis in the pathogenesis and treatment of disease. Science, 1995, 267 (5203) : 1456-1462.
  • 3Favaloro B, Allocati N, Graziano V, et al. Role of apoptosis in disease. Aging (Albany NY) , 2012, 4(5) :330-349.
  • 4Vermes I, Haanen C, Steffens-Nakken H, et al. A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early apoptotic cells using fluorescein labelled Annexin V. J Immunol Methods, 1995, 184(1) :39-51.
  • 5van Engeland M, Nieland L J, Ramaekers F C, et al. Annexin Vaffinity assay: a review on an apoptosis detection system based on phosphatidylserine exposure. Cytometry, 1998, 31 ( 1 ) : 1-9.
  • 6Ke N,Wang X, Xu X, et al. The xCELLigence system for real-time and label-free monitoring of cell viability. Methods Mol Biol, 2011, 740:33 -43.
  • 7Dowling C M, I"Ierranz Ors C, Kiely P A. Using real-time impedance-based assays to monitor the effects of fibroblast-derived media on the adhesion, proliferation, migration and invasion of colon cancer cells. Biosci Rep, 2014, 34(4). pii: e00126.
  • 8Roshan Moniri M, Young A, Reinheimer K, et al. Dynamic assessment of cell viability, proliferation and migration using real time cell analyzer system (RTCA). Cytotechnology, 2015, 67 (2) : 379-86.
  • 9Jonsson M K, Wang Q D, Becker B. Impedance-based detection of beating rhythm and proarrhythmic effects of compounds on stem cell- derived cardiomyocytes. Assay Drug Dev Technol, 2011, 9 (6) : 589-599.
  • 10Wyllie A H. "Where, 0 death, is thy sting?" A brief review of apoptosis biology. Mol Neurobiol, 2010, 42 ( 1 ) : 4-9. doi: 10. 1007/s12035-010-8125-5.

同被引文献33

引证文献3

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部