期刊文献+

风电场工程节能评估中电能损耗计算的探讨 被引量:1

Discussion of calculation for loss of power in the wind farm energy-saving assessment process
下载PDF
导出
摘要 目前,风电场节能评估中电能损耗的计算方法和组成有很大差别,文中讨论并计算风机自身耗电的选取、线路和变压器的无功损耗的计算、主变的负载率、站用变压器利用小时数和负载率的选择、无功补偿装置的损耗计算等。建立了较完善的电能损耗计算体系,为今后各个风电场工程节能评估工作的顺利进行提供了重要的计算依据。 The calculation method and composition of electric energy loss in wind farm energy saving assessment are very different.This paper discusses the calculation of the power consumption of the wind turbine,the calculation of the reactive power loss of the circuit and the transformer,the load rate of the main transformer,the choice of the number of load and the loss calculation of reactive power compensation device.The calculation system of electric energy loss is established,which provides an important basis for the future work of the wind farm project energy saving assessment.
出处 《节能》 2016年第1期35-37,3,共3页 Energy Conservation
关键词 风电场 节能 评估 电能损耗 wind farm energy-saving assessment power less
  • 相关文献

参考文献3

  • 1国家发展改革委员会.固定资产投资项目节能评估和审查暂行办法[EB/OL].http://www.sdpc.gov.cn/zcfb/zcfbl/20101ing/t20100921_372517.htm,2010-09-17.
  • 2沈景霆.对变压器经济运行及容量节能选择若干问题的探讨[J].电气工程应用,1991,0(3):27-32. 被引量:3
  • 3中国航空工业规划设计研究院.工业与民用供配电设计手册[M].北京:中国电力出版社,2005.