摘要
本文介绍了国内某350 MW超临界锅炉在机组运行期间,2#炉后烟道前包墙边管多次泄露并吹损集箱的原因分析,问题处理及后续改进措施。
During the operation of a 350 MW supercritical boiler,The backpass front wall tube of 2#boiler leaked and blow loss header. Through analysis of the questions above,We have developed a solution. And improvements to optimize the structure of this type of boiler.
出处
《锅炉制造》
2016年第2期20-21,共2页
Boiler Manufacturing
关键词
超临界
泄露
快速启停
热胀差
supercritical
leakage
rapid start-stop
differential thermal expansion