摘要
冷却水管在碾压混凝土施工中极易受到破坏,通过系统分析复杂施工过程中碾压混凝土冷却水管损坏与位移,归纳总结了在施工过程中可能造成冷却水管破坏的风险因素。将这些因素通过不同工况进行分析,计算得出冷却水管损坏与移位情况。将研究所用方法应用于实际工程,通过计算分析冷却水管的位移及最大压应力,为冷却水管的定位铺设和外观保护提供了理论参考。
As the water-cooling pipe is prone to be damaged during RCC construction, the risk factors those possibly causing the damage of the cooling-water pipe during the construction are summarized herein through a systematical analysis made on both the damage and displacement of the RCC cooling-water pipe during the complicated construction, and then the damage and displace- ment of the cooling-water pipe are calculated as well. Applied the study result to the actual project, some theoretical references for positioning and placing the cooling-water pipe as well as the protection of its appearance are provided through the calculation and analysis made on the displacement and the maximum compressive stress.
出处
《水利水电技术》
CSCD
北大核心
2016年第1期41-44,48,共5页
Water Resources and Hydropower Engineering
基金
国家重点基础研究发展"973"计划(2013CB035904)
国家创新研究群体科学基金(51021004)
教育部新世纪优秀人才计划(NCET-12-0404)
关键词
冷却水管
碾压混凝土施工
损坏与移位
力学分析
water-cooling pipe
RCC construction
displacement and damage
mechanical analysis