期刊文献+

鼻咽癌IMRT两种不同体位固定方法的摆位误差分析 被引量:10

原文传递
导出
摘要 IMRT作为鼻咽癌首选治疗方式,其对肿瘤定位、治疗计划设计和治疗实施都有很高的精度要求。摆位误差是放疔过程中影响精确放疗的重要因素,因此通过分析两种不同体位固定方法下鼻咽癌患者群体摆位误差大小及分布情况,探讨鼻咽癌患者更为合理的体位固定方法,可为临床放疗及质量控制提供理论依据。
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2016年第3期226-227,共2页 Chinese Journal of Radiation Oncology
  • 相关文献

参考文献4

  • 1Stroom JC, de Boer HCJ, Huizenga H, et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability [J].Int J Radiat Oncol Biol Phys, 1999,43 ( 4 ) : 905 -919. DO I : I 0.1016/S0360 - 3016 ( 98 ) 00468 -4.
  • 2张华满,向燕群,伍建华,林刘文,姜晓勃,邵剑辉,方键蓝,韩非,林承光.个体化头颈肩体位固定在鼻咽癌调强放疗中的应用分析[J].中华放射肿瘤学杂志,2012,21(2):185-185. 被引量:10
  • 3潘建基,潘才住,陈传本,张秀春,柏朋刚.摆位系统误差对鼻咽癌调强放疗剂量的影响[J].中华放射肿瘤学杂志,2007,16(5):394-396. 被引量:43
  • 4Astreinidou E, Bel A, Raaijmakers CPJ, et al. Adequate margins for random Setup uncertainties in head-and-neck IMRT[J]. Int J Radiat Oncol Biol Phys, 2005,61 ( 3 ) : 938-944. DOI : 10. 1016/j. ijrobp.2004.11.016.

二级参考文献14

  • 1Hong TS, Tome WA, Chappeii R J, et al. The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys,2005,61:779-788.
  • 2Hunt M. The effect of positional uncertainties on the treatment of primary nasopharynx cancer. Med Phys, 1989,16:456 - 464.
  • 3Stroom JC, de Boer JC, Huizenga H, et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. Int J Radiat Oncol Biol Phys, 1999,43:905-919.
  • 4Stroom JC, Heijmen BJ. Geometrical uncertainties, radiotherapy planning margins, and the ICRU - 62 report. Radiother Oncol, 2002,64:75 - 83.
  • 5ICRU Report 50: prescribing, recording, and reporting photon beam therapy. Bethesda:Intemational Commission on Radiation Units and Measurements(ICRU), 1993 : 1-72.
  • 6ICRU Report 62: prescribing, recording, and reporting photon beam therapy (Supplement to ICRU Report 50). Bethesda: International Commission on Radiation Units and Measurements (ICRU), 1999:1-51.
  • 7Butler EB, The BS, Grant WH, et al. Smart Boost: a new accelerated fractionation schedule for the treatment of head and neck cancer with intensity modulated radiotherapy. Int J Radiat Oncol Biol Phys, 1999,45:21-32.
  • 8Kuppersimith RB, Greao SC, The BS, et al. Intensity modulated radiotherapy: first result with this new technology on neoplasms of the head and neck. Ear Nose Throat J, 1999,78:238-241.
  • 9Moham R, Wu Q, Manning M, et al. Radiobiological considerations in the design of fractionation strategies for intensity modulated radiation therapy of head and neck cancers. Int J Radiat Oncol Biol Phys, 2000,46:619-630.
  • 10Siebers JV, Keall PJ, Wu Q, et al. Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treatment plans. Int J Radiat Oncol Biol Phys ,2005 ,63 :422-433.

共引文献49

同被引文献81

引证文献10

二级引证文献45

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部