优化了电感耦合等离子体原子发射光谱测定氯元素的分析参数,考察了空白溶剂和干扰元素对测定氯的影响。用电感耦合等离子体原子发射光谱测定润滑油中氯的相对标准偏差(n=8)≤4.46%,测定氯标准物质的相对误差≤5%。
The analysis parameters of inductively coupled plasma atomic emission spectrometry were opti- mized to determinate chlorine, the impacts of blank solvents and interfering elements on determination of chlorine were examined.The relative standard deviation (n=8) of determination of chlorine was ≤4.46%, and the relative error of determination of chlorine standard specimen was ≤5% by inductively coupled plasma atomic emission spectrometry
出处
《合成润滑材料》
CAS
2016年第1期7-10,共4页
Synthetic Lubricants
关键词
润滑油
氯
电感耦合等离子体原子发射光谱
空白溶剂
干扰元素
lubricants
chlorine
inductively coupled plasma atomic emission spectrometry
blank sol-vents
interfering elements