期刊文献+

工艺误差对电容式微加速度计温度漂移的影响(英文)

Effects of fabrication error on thermal drift of capacitive micro accelerometer
下载PDF
导出
摘要 利用有限元方法,仿真分析了深反应离子刻蚀工艺造成的折叠梁宽度误差对电容式微加速度计温度漂移的影响。在存在工艺误差和保证微加速度计灵敏度恒定的前提下,增大了折叠梁设计宽度,计算了不同宽度下微加速度计的温度漂移量。结果表明:刻蚀工艺误差越大,微加速度计温度漂移量越大。折叠梁设计宽度为4.5μm和6.5μm时,最大温度漂移量分别为2.42mg/℃和1.71mg/℃,因此通过适当地增大设计尺寸,可以有效地减小微加速度计的温度漂移量。 Dimension uncertainty inevitably occurs in almost every fabrication of micro structure due to itssmall size and uniformity of material. The dimension error, however, will result in the asymmetry of the sensitive structure. The unsymmetrical structure will change the distribution of the thermal stress when the microsensors are subjected to changed temperature and further impact the thermal stability of devices which is characterized by the quantity of thermal drift. This study investigates the effects of fabrication error on the thermaldrift of a comb capacitive micro accelerometer fabricated by deep reactive ion etching(DRIE) process. The accelerometers with supporting folded beams width error ranging from the ideal layout design to the actual fabricateddimension are modeled to simulate the deformation of sensitive component induced by temperature change. Thethermal drifts are acquired by the calculation of the differential capacitance of the deformed structure. In orderto reduce the thermal drift induced by the fabrication error, the design dimension of the beam width is enlargedunder the premise of constant sensitivity of the accelerometer. The calculated results indicate that the supporting beam fabrication error will significantly affect the thermal drift of the capacitive micro accelerometers and anincreased design dimension of the beam width can improve the symmetry of the sensor, and then reduce thethermal drift.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第6期122-125,共4页 High Power Laser and Particle Beams
基金 supported by NSAF(U1530132) National Natural Science Foundation of China(51505068,51575090) Fundamental Research Funds for the central universities(ZYGX2013J097)
关键词 工艺误差 电容式微加速度计 温度漂移 fabrication error capacitive micro accelerometer thermal drift
  • 相关文献

参考文献3

二级参考文献43

  • 1U. Krishnamoorthy,R.H. Olsson,G.R. Bogart,M.S. Baker,D.W. Carr,T.P. Swiler,P.J. Clews.In-plane MEMS-based nano-g accelerometer with sub-wavelength optical resonant sensor[J]Sensors & Actuators: A Physical,2008.
  • 2Litao Qi,Kazuhiro Nishii,Motohiro Yasui,Hikoharu Aoki,Yoshiharu Namba.Femtosecond laser ablation of sapphire on different crystallographic facet planes by single and multiple laser pulses irradiation[J]. Optics and Lasers in Engineering . 2010 (10)
  • 3Hsu, E.M.,Mailman, N.A.,Botton, G.A.,Haugen, H.K.Microscopic investigation of single-crystal diamond following ultrafast laser irradiation. Applied Physics . 2011
  • 4Sorenson L D,Shao P,Ayazi F.Effect of thickness anisotropy on degenerate modes in oxide micro-hemispherical shell resonators. Micro Electro Mechanical Systems (MEMS) . 2013
  • 5Sudheer,S.K,Pillai,V.P.M,Nayar,V.U.Characterization of Laser Processing of Single -crystal Natural Diamonds Using Micro-Raman Spectroscopic Investigations. J.of Raman Spectrosc . 2007
  • 6Cho J,Yan J,Gregory J A.High-Q fused silica birdbath and hemispherical 3-D resonators made by blow torch molding. 26th IEEE International Conference on Micro Electro Mechanical Systems (MEMS) . 2013
  • 7Alexandre B,Emmanuel S,Lionel R.Selective nucleation in silicon moulds for diamond MEMS fabrication. Journal of Micromechanics and Microengineering . 2009
  • 8J. Lai,T. Perazzo,Z. Shi,A. Majumdar.Optimization and performance of high-resolution micro-optomechanical thermal sensors[J]. Sensors & Actuators: A. Physical . 1996 (2)
  • 9Vollmer Frank,Arnold Stephen.Whispering-gallery-mode biosensing: label-free detection down to single molecules. Nature methods . 2008
  • 10De Vos Katrien,Bartolozzi Irene,Schacht Etienne,Bienstman Peter,Baets Roel.Silicon-on-Insulator microring resonator for sensitive and label-free biosensing. Optics Express . 2007

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部