摘要 介绍一种新的标准尘埃粒子计数器校准方法,通过"尘埃粒子计数器—凝结核粒子计数器—气溶胶静电计"的逐级溯源链,将尘埃粒计数器的计数值溯源至电流基准,形成一个完整的溯源体系。结果表明,该方法可以对尘埃粒子计数器量程内粒径的计数效率进行评估,解决各种流量的尘埃粒子计数器的校准问题。 A new calibration method for the standard optical particle counter was introduced. According to the stepwise traceability chain of optical particle counter —condensation nucleus counter —aerosol electrometer,the count value of optical particle counter could be traced to the current standard. A complete traceability system was formed. The results show that this method can not only evaluate the counting efficiencies of optical particles in different radius ranges,but also solve the calibration problem in different flow rates.
出处 《中国粉体技术》 CAS 北大核心 2016年第1期80-82,共3页 China Powder Science and Technology
基金 国家重大科学研究计划项目 编号:2011CB932802 中国计量科学研究院基本科研项目 编号:31-AKY1328-13
关键词 尘埃粒子计数器 溯源 计数效率 流量 optical particle counter traceability counting efficiency flow
  • 相关文献

参考文献6

  • 1国家质量监督检验检疫总局.JJF 1190—2008尘埃粒子计数器校准规范[S].北京:中国计量出版社,2008.
  • 2刘俊杰,张文阁,胡向军.气溶胶静电计的校准研究[C]//第九届全国颗粒测试学术会议暨现代颗粒测试技术发展与应用研讨会论文集,2013:60-64.
  • 3刘俊杰,张文阁,国凯,任玲玲.尘埃粒子计数器校准装置的研制[J].计量技术,2014(10):48-51. 被引量:8
  • 4OWEN M C.An aerosol number concentration primary standard[R].2006 NCSL international workshop and symposium,2006.
  • 5FLETCHER R A,MULHOLLAND G W.Calibration of a condensation particle counter using a NIST traceable method[J].Aerosol Science and Technology,2009,43:425-441.
  • 6International Organization for Standardization.ISO 21501-4—2007Determination of particle size distribution:single particle light interaction methods:parts 4:light scattering airborne particle counter for clean spaces[S].Geneva:ISO,2007.

二级参考文献9

  • 1纪运景,卞保民,贺安之.不同光源对激光尘埃粒子计数器性能的影响[J].红外与激光工程,2004,33(3):264-268. 被引量:10
  • 2陈成新,李名兆.尘埃粒子计数器的原理和使用[J].工业计量,2004,14(6):33-35. 被引量:16
  • 3R. A. Fletcher, G. W. Mulholland, Calibration of a Condensation par- ticle counter using a NIST Traceable Method, Aerosol Science and Technology ,2009,43,425 - 441.
  • 4Miles Owen, George Mulholland and Will Guthrie, Condensation par- ticle counter proportionality ealibration from 1 particle ~ cm -3 to 104 particles ~ cm-3, Aerosol Science and Technology, 2012,46,444 - 450.
  • 5Hiromu Sakurai, Kensei Ehara, Evalution of uncertainties in femto- ampere current measurement for the number concentration standard of aerosol nanoparticles, Measurement Science and Technology, 2011,22,1 - 11.
  • 6Miles Owen, Calibration of an Electrometer from 500fA to 100fA, 2006 NCSL International Workshop and Symposium.
  • 7刘俊杰,张文阁,胡向军.气溶胶静电计的校准研究.第九届全国颗粒测试学术会议暨现代颗粒测试技术发展与应用研讨会论文集(第十五届中国科协年会第16分会场),2013.
  • 8朱弋,王振洲,李朝伟.空气粒子计数器原理及手术室洁净度检测要求[J].医疗装备,2011,24(3):40-41. 被引量:4
  • 9刘俊杰,张文阁,胡向军,郝新友.JJG1061-2010《液体颗粒计数器》检定规程解读[J].中国计量,2011(11):120-122. 被引量:2

共引文献9

同被引文献7

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部