期刊文献+

Simultaneous denitrification and denitrifying phosphorus removal in a full-scale anoxic–oxic process without internal recycle treating low strength wastewater 被引量:10

Simultaneous denitrification and denitrifying phosphorus removal in a full-scale anoxic–oxic process without internal recycle treating low strength wastewater
原文传递
导出
摘要 Performance of a full-scale anoxic-oxic activated sludge treatment plant(4.0×10-5 m-3/day for the first-stage project) was followed during a year.The plant performed well for the removal of carbon,nitrogen and phosphorus in the process of treating domestic wastewater within a temperature range of 10.8℃ to 30.5℃.Mass balance calculations indicated that COD utilization mainly occurred in the anoxic phase,accounting for 88.2% of total COD removal.Ammonia nitrogen removal occurred 13.71% in the anoxic zones and 78.77% in the aerobic zones.The contribution of anoxic zones to total nitrogen(TN) removal was 57.41%.Results indicated that nitrogen elimination in the oxic tanks was mainly contributed by simultaneous nitrification and denitrification(SND).The reduction of phosphorus mainly took place in the oxic zones,51.45% of the total removal.Denitrifying phosphorus removal was achieved biologically by 11.29%.Practical experience proved that adaptability to gradually changing temperature of the microbial populations was important to maintain the plant overall stability.Sudden changes in temperature did not cause paralysis of the system just lower removal efficiency,which could be explained by functional redundancy of microorganisms that may compensate the adverse effects of temperature changes to a certain degree.Anoxic-oxic process without internal recycling has great potential to treat low strength wastewater(i.e.,TN 〈 35 mg/L) as well as reducing operation costs. Performance of a full-scale anoxic-oxic activated sludge treatment plant(4.0×10-5 m-3/day for the first-stage project) was followed during a year.The plant performed well for the removal of carbon,nitrogen and phosphorus in the process of treating domestic wastewater within a temperature range of 10.8℃ to 30.5℃.Mass balance calculations indicated that COD utilization mainly occurred in the anoxic phase,accounting for 88.2% of total COD removal.Ammonia nitrogen removal occurred 13.71% in the anoxic zones and 78.77% in the aerobic zones.The contribution of anoxic zones to total nitrogen(TN) removal was 57.41%.Results indicated that nitrogen elimination in the oxic tanks was mainly contributed by simultaneous nitrification and denitrification(SND).The reduction of phosphorus mainly took place in the oxic zones,51.45% of the total removal.Denitrifying phosphorus removal was achieved biologically by 11.29%.Practical experience proved that adaptability to gradually changing temperature of the microbial populations was important to maintain the plant overall stability.Sudden changes in temperature did not cause paralysis of the system just lower removal efficiency,which could be explained by functional redundancy of microorganisms that may compensate the adverse effects of temperature changes to a certain degree.Anoxic-oxic process without internal recycling has great potential to treat low strength wastewater(i.e.,TN 〈 35 mg/L) as well as reducing operation costs.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第1期175-183,共9页 环境科学学报(英文版)
基金 supported by the National High Technology Research and Development Program (863 Program) of China (No. 2012AA063302) the Jiangsu Water Protection Project (No. 2015005)
关键词 Wastewater treatment Biological nutrient removal Simultaneous nitrification and denitrification Denitrifying phosphorus removal Wastewater treatment Biological nutrient removal Simultaneous nitrification and denitrification Denitrifying phosphorus removal
  • 相关文献

参考文献38

  • 1Amanatidou, E., Samiotis, G., Trikoilidou, E., Pekridis, G., Taousanidis, N., 2015. Evaluating sedimentation problems in activated sludge treatment plants operating at complete sludge retention time. Water Res. 69, 20-29.
  • 2APHA, 2005. Standard methods for the examination of water and wastewater. American Public Health Association, 21th ed. American Water Works Association and Water Environment Federation, Washington DC, USA.
  • 3Biradar, P.M., Roy, S.B., D'Souza, S.F., Pandit, A.B., 2010. Excess cell mass as an internal carbon source for biological denitrification. Bioresour. Technol. 101 (6), 1787-1791.
  • 4Cao, G., Wang, S., Peng, Y., Miao, Z., 2013. Biological nutrient removal by applying modified four step-feed technology to treat weak wastewater. Bioresour. Technol. 128, 604-611.
  • 5Erdal, U.G., Erdal, Z.K., Randall, C.W., 2003. The competition between PAOs (phosphorus accumulating organisms) and GAOs (glycogen accumulating organisms) in EBPR (enhanced biological phosphorus removal) systems at different temperatures and the effects on system performance. Water Sd. Technol. 47 (11), 1-8.
  • 6Feller, G., 2003. Molecular adaptations to cold in psychrophilic enzymes. Cell. Mol. Life Sci. 60 (4), 648-662.
  • 7Femandes, H., Jungles, M.K., Hoffmann, H., Antonio, R.V., Costa, R.H.R., 2013. Full-scale sequencing batch reactor (SBR) for domestic wastewater: performance and diversity of microbial communities. Bioresour. Technol. 132, 262-268.
  • 8Flowers, J.J., Cadkin, T.A., McMahon, K.D., 2013. Seasonal bacterial community dynamics in a full-scale enhanced biological phosphorus removal plant. Water Res. 47 (19), 7019-7031.
  • 9Gong, L., Huo, M., Yang, Q., Li, J., Ma, B., Zhu, R., et al., 2013. Performance of heterotrophic partial denitrification under feast-famine condition of electron donor: a case study using acetate as external carbon source. Bioresour. Technol. 133, 263-269.
  • 10Guerrero, J., Guisasola, A., Comas, J., Rodriguez-Roda, I., Baeza, LA., 2012. Multi-criteria selection of optimum WVFP control setpoints based on microbiology-related failures, effluent quality and operating costs. Chem. Eng. J. 188, 23-29.

同被引文献98