讲述了300MW发电机线圈出水测温元件不锈钢接头在现场运行渗漏后的处理,并在分析原因后,对该零件进行了改进。
Treatment of water-leakage at the stain- less-steel joints of temperature-measuring elements in the stator coil of 300 MW generator was introduced. Improve- ment on the part was done after analyzing the leakage cause.
出处
《电机技术》
2016年第1期33-34,40,共3页
Electrical Machinery Technology
关键词
不锈钢接头
漏水
缩孔