1Y Watabe Y, Kondo T, Morita M, et al. Determination of bisphenol h in envirorunental water at ultra-low level by high- performance liquid chromatography with an effective on-line pretreatment device[J]. J. Chromatography A. 2004(39), 45-49.
2Kawaguchi M, Inoue K, Yoshimura M, et al. Determination of bisphenol A in river water and body fluid samples by stir bar sorptive extraction with in situ derivatization and thermal desorption-gas chromatography-mass spectrometry [J]. J. Chromatography B, 2004(805):41-48.
3Inoue K, Kato K, Yoshimura Y, et al. Determination of bisphenol A in human serum by high-performance liquid chromatography with multi-electrode electrochemical detection [J]. LChromatography B, 2000(749):17-23.
4Sun Y, Irie M, Kishikawa N, et al. Determination of bisphenol h in human breast milk by HPLC with column- switching and fluorescence detection [J] Biomed. Chromatogr, 200(18):501 - 507.
5Rezaee M, Yamini Y, Shariati S, et al. Dispersive liquid- liqgid microextraction combined with high-performance liquid chromatography-UV detection as a very simple, rapid and sensitive method for the determination of bisphenol h in water samples [J]. J. Chromatography h. 2009(121), 1511 - 1514.
6Sajiki J, Takahashi K, Yonekubo J.. Sensitive method for the determination of bisphenol-h in serum using two systems of high-performance liquid chromatography [J]. J. Chromatography B, 1999(736):255 - 261.
7Inoue K, Wada M, Higuchi T, et al. Application of liquid chromatography-mass spectrometry'to the quantification of bisphenol A in human semen [J]. J. Chromatography B. 2002(773):97-102.
8Kawaguchi M, Inoue K, Yoshimura M, et al. Determination of bisphenol A in river water and body fluid samples by stir bar sorptive extraction with in situ derivatization and thermal desorption- gas chromatography-mass spectrometry [J]. J. Chromatography B, 2004(805):41-48.
9Xiao n Z, Lan n L, Wei Q X, et al. Selective determination of bisphenol h in water by a reversible fluorescence sensor using pyrene/dimethyl-cyclodextrin complex[J].hnalytica Chimica hcta, 2006(556):313-318.
10Kim Y, Jeon J B, Chang J Y. CdSe quantum do encapsulated molecularly imprinted mesoporous silica particles for fluorescent sensing of bisphenol A[J].J. Mater. Chem.2012 (22): 24075 - 24080.
二级参考文献61
1Collinson M M . Crit. Rev. Anal. Chem., 1999, 29: 289~311.
2Lev O, Tsionsky M , Rabinovich L, Glezer V, Sampath S, Pankratov I, Gun J. Anal. Chem., 1995, 67: 22A~30A.
3Lin J , Brown C W. Trends Anal. Chem., 1997, 14: 200~211.
4Blum J, Avnir D, Schumann H. Chemtech., 1999, 29(2): 32~38.
5Ingersoll C N, Bright F V. Chemtech., 1997, 27(1): 26~31.
6Brinker C J, Raman N K, Logan M N, Swhgal R, Assink R-A, Hua D-W, Ward T L. J. Sol-Gel Sci. Technol., 1995, 4: 117~133.
7Hayes J D, Malik A. Anal. Chem., 2001, 73: 987~996.
8Chen Z, Hobo T. Anal. Chem., 2001, 73: 3348~3357.
9Bigham S, Medlar J, Kabir A, Shende C, Alli A, Malik A. Anal. Chem., 2002, 74: 752~761.
10Zeng Z, Hobo T. Anal. Chem., 2001, 73: 2429~2436.