期刊文献+

Utilisation of waste heat from exhaust gases of drying process 被引量:1

Utilisation of waste heat from exhaust gases of drying process
原文传递
导出
摘要 Nowadays a lot of low-grade heat is wasted from the industry through the off- and flue-gasses with different compositions. These gases provide the sensitive heat with utilisation potential and latent heat with the components for condensation. In this paper, process integration methodology has been applied to the partly condensed streams. A hot composite curve that represents the gas mixture cooling according to equation of state for real gases was drawn to account the gas-liquid equilibrium. According to the pinch analysis methodology, the pinch point was specified and optimal minimal temperature difference was determined. The location of the point where gas and liquid phases can be split for better recuperation of heat energy within heat exchangers is estimated using the developed methodology. The industrial case study of tobacco drying process off-gasses is analysed for heat recovery. The mathematical model was developed by using MathCad software to minimise the total annualised cost using compact plate heat exchangers for waste heat utilisation. The obtained payback period for the required investments is less than six months. The presented method was validated by comparison with industrial test data. Nowadays a lot of low-grade heat is wasted from the industry through the off- and flue-gasses with different compositions. These gases provide the sensitive heat with utilisation potential and latent heat with the components for condensation. In this paper, process integration methodology has been applied to the partly condensed streams. A hot composite curve that represents the gas mixture cooling according to equation of state for real gases was drawn to account the gas-liquid equilibrium. According to the pinch analysis methodology, the pinch point was specified and optimal minimal temperature difference was determined. The location of the point where gas and liquid phases can be split for better recuperation of heat energy within heat exchangers is estimated using the developed methodology. The industrial case study of tobacco drying process off-gasses is analysed for heat recovery. The mathematical model was developed by using MathCad software to minimise the total annualised cost using compact plate heat exchangers for waste heat utilisation. The obtained payback period for the required investments is less than six months. The presented method was validated by comparison with industrial test data.
出处 《Frontiers of Chemical Science and Engineering》 SCIE EI CAS CSCD 2016年第1期131-138,共8页 化学科学与工程前沿(英文版)
关键词 exhaust gas waste heat process integration plate heat exchanger exhaust gas, waste heat, process integration, plate heat exchanger
  • 相关文献

参考文献29

  • 1OECD/IEA. World Energy Outlook 2013. 2015, http://www. worldenergyoutlook.org/weo2013/.
  • 2Kleme~ J, Friedler F, Bulatov I, Varbanov P. Sustainability in the process industry. Integration and optimization. New York: The McGraw-Hill Co-s. lnc, 2010.
  • 3Oluleye G, Jobson M, Smith R, Perry S J. Evaluating the potential of process sites for waste heat recovery. Applied Energy, 2016, 161: 627-646.
  • 4Khaled M, Ramadan M, El Hage H. Parametric analysis of heat recovery from exhaust gases of generators. Energy Procedia, 2015, 75:3295-3300.
  • 5Kilkovsky B, Stehlik P, Jegla Z, Tovazhnyansky L L, Arsenyeva O, Kapustenko P O. Heat exchangers for energy recovery in waste and biomass to energy technologies I. Energy recovery from flue gas. Applied Thermal Engineering, 2014, 64(1): 213-223.
  • 6Szulc P, Tietze T, W6js K. Numerical analysis of a waste heat recovery process with account of condensation of steam from flue gases. Archives of Civil and Mechanical Engineering, 2015, 15(4): 1017 -1023.
  • 7Maalouf S, Ksayer E B, Clodic D. Investigation of direct contact condensation for wet flue-gas waste heat recovery using Organic Rankine Cycle. Energy Conversion and Management, 2016, 107: 96-102.
  • 8Zegenhagen M T, Ziegler F. Simple models for the heat exchange from exhaust gas to super- and sub-critical refrigerant R134a at high temperature differences. Applied Thermal Engineering, 2015, 89: 990 -1000.
  • 9Han X, Liu M, Wang J, Yan J, Liu J, Xiao F. Simulation study on lignite-fired power system integrated with flue gas drying and waste heat recovery-Performances under variable power loads coupled with off-design parameters. Energy, 2014, 76:406-418.
  • 10Xu C, Xu G, Yang Y, Zhao S, Zhang K, Zhang D. An improved configuration of low-temperature pre-drying using waste heat integrated in an air-cooled lignite fired power plant. Applied Thermal Engineering, 2015, 90:312-321.