期刊文献+

分轴联合循环机组旁路快开优化控制

Optimal Control on Fast Opening of Bypass on Multiple Shaft Combined Cycle Power Unit
下载PDF
导出
摘要 分轴式联合循环机组在汽轮机跳闸时,旁路系统可靠地快开能够有效抑制蒸汽压力及温度波动,维持余热锅炉及燃汽轮机正常运行,从而缩小事故范围,减少机组损失。通过旁路通流试验可以获得准确的阀门开度参数,用以优化旁路快开控制逻辑,提高事故工况下对蒸汽压力及温度的控制精度,对保障联合循环机组运行安全可靠有重要价值。 The reliable fast opening of bypass system can control steam pressure fluctuation when the ST trips in mul- tiple shaft combined cycle power unit. Thus it can maintain HRSG and GT to run,reduce the accident scope and de- crease the loss of the unit. The opening value of the valves can be got exactly through bypass capacity test to optimize the logic of bypass,therefore the accuracy to control the pressue and tempreture of steam is improved. It is valuable for combined cycle power unit to run more safely and reliably.
作者 司派友
出处 《华北电力技术》 CAS 2016年第3期42-47,53,共7页 North China Electric Power
关键词 联合循环 分轴 旁路 快开 通流试验 combined cycle, multiple shaft, bypass system, fast opening, capacity test
  • 相关文献

参考文献9

二级参考文献24

  • 1刘尚明,王纯.燃气轮机及联合循环一次调频控制综述[J].热力透平,2004,33(3):154-157. 被引量:20
  • 2郑仁武.燃气发电机组运行故障分析和维修措施[J].设备管理与维修,2006(1):18-19. 被引量:7
  • 3胡宗武 董邦宣.雨流法与疲劳寿命估算[J].机械强度,1985,7(4).
  • 4FUCHS H O, STEPHES R I. Metal Fatigue in Engineering [M]. New York: John Wiley & Sons, 1980.
  • 5中平高明.蒸汽轮机转子的非定常热应力.TSME,1971,74(8):8-12.
  • 6吴富民 聂宏.关于雨流计数法的讨论及修正.航空学报,1986,7(3):242-247.
  • 7聂景旭 李纪安 聂聪.涡轮盘及槽底瞬态温度场及应力场分析.北京航空航天大学学报,1982,28(1):29-40.
  • 8MATSUISKI M, ENDO T. Fatigue of metals subjected to varying stress[M]. Fukuoka, Japan: Kyushu Branch of Japan SME, 1968.
  • 9Siemens AG. Description of the unit coordination program for Shanghai Shidongkou Combined Cycle, Project [Z].2005.
  • 10中周华北电力集团公司.京津唐电网自动发电控制(AGC)运行管理办法(试行)[S].2002.