摘要
针对大干扰电网稳定鉴别具体问题,提出一种应用解耦仿真分析鉴别功角稳定失稳主要诱因的方法,介绍该方法在典型故障案例中的实施过程,通过结论分析验证了该方法的正确性。
Due to a large disturbance power grid angle stability identification problem,a method to identify the chief incentive of powerangle unstability by de-couple simulation analysis was proposed. The proposed method was expounded by operating procedure of a typical fault case,The results of application verified the correctness of the identification method.
出处
《河北电力技术》
2016年第1期30-33,共4页
Hebei Electric Power
关键词
解耦仿真
功角稳定
大干扰
大电网
decoupling simulation
angle instability
large disturbance
bulk power grid