期刊文献+

迟发性起搏器囊袋感染的保守治疗策略及文献复习 被引量:1

下载PDF
导出
摘要 目的:探讨迟发性起搏器囊袋感染保守治疗的条件及措施。方法:回顾分析6例起搏器植入术后囊袋感染出现的时间、临床表现、辅助检查、处理过程及预后。结果:6例患者均为迟发性囊袋感染,无发热、寒战等全身感染症状,局部主要表现为红肿、触痛,有波动感,炎性标志物阴性,经胸超声心动图未见赘生物形成,无糖尿病、慢性肾衰竭、慢性阻塞性肺疾病及消耗体质等慢性疾病史,经局部清创、消毒及抗感染等保守治疗后病情稳定,伤口愈合良好。结论:迟发性起搏器囊袋感染患者无全身感染证据时可实施保守治疗策略,预后良好。
出处 《临床医药实践》 2016年第3期191-194,共4页 Proceeding of Clinical Medicine
  • 相关文献

参考文献16

  • 1SOHAIL M R,HUSSAIN S,LE K Y,et al.Risk factors associated with early-versus late-onset implantable cardioverter-defibrillator infections[J].J Interv Card Electrophysiol,2011,31(2):171-183.
  • 2BADDOUR L M,EPSTEIN A E,ERICKSON C C,et al.Update on cardiovascular implantable electronic device infections and their management:a scientific statement from the American Heart Association[J].Circulation,2010,121(3):458-477.
  • 3GOLZIO P G,D'ASCENZO F,PERVERSI J,et al.Analysis of extracted cardiac device leads for bacteria type:clinical impact[J].Expert Rev Cardiovasc Ther,2013,11(9):1237-1245.
  • 4GOLZIO PG,VINCI M,ANSELMINO M,et al.Accuracy of swabs,tissue specimens,and lead samples in diagnosis of cardiac rhythm management device infections[J].Pacing Clin Electrophysiol,2009,32(Suppl 1):76-80.
  • 5SOPEA B,CRESPO M,BEIRAS X,et al.Individualized management of bacteraemia in patients with a permanent endocardial pacemaker[J].Clin Microbiol Infect,2010,16(3):274-280.
  • 6TAYEBJEE M H,JOY E R,SANDOE J A.Can implantable cardiac electronic device infections be defined as early or late based on the cause of infection[J].J Med Microbiol,2013,62(Pt 8):1215-1219.
  • 7MARIA G B,CARLO T.Microbiology of cardiac implantable electronic device infections[J].Europace,2012,14(9):1334-1339.
  • 8GOULD P A,GULA L J,YEE R,et al.Cardiovascular implantable electrophysiological device-related infections:a review[J].Curr Opin Cardiol,2011,26(1):6-11.
  • 9KLUG D,WALLET F,LACROIX D,et al.Local symptoms at the site of pacemaker implantation indicate latent systemic infection[J].Heart,2004,90(7):882-886.
  • 10心律植入装置感染与处理的中国专家共识2013[J].临床心电学杂志,2013,22(4):241-253. 被引量:81

二级参考文献10

  • 1Love C J, Wilkoff BL, Byrd CL et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty. Pacing Clin Electrophysiol, 2000;23:544.
  • 2Darouiche RO. Trealment of infections ass iated with surgical implants. N Engl J Med, 2004;350:1422.
  • 3Baddour LM, Epstein AE, Erickson CC et al. Update on cardiovascular implantahle electronic device infections and their management: a scientific statement from the American Heart Association. Circulation, 2010;121:458.
  • 4Wilkoff BL, Love C J, Byrd CLet al. Transvenous lead extraction: Heart Rhythm S icty expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm, 2009;6:1085.
  • 5Greenspon AJ, Patel JD, Lau E et al. 16-year trends in the infection burden for pacemakers and implantable cardi 111 the United States 1993 to 2008. J Am Coil Cardiol, 2011;58:1001.
  • 6S.M. Kurtz, J.A. Ochoa, E. Lau et al.Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006.Pacing Clin Electrophysiol, 2011;33: 705.
  • 7Arnold J. Greenspon, Jasmine D. Patel, Edmund Lau et al. Trends in Permanent Pacemaker Implantation in the United States From 1993 to 2009: Increasing Complexity of Patients and Procedures. J Am Coil Cardiol,60:1540.
  • 8S.M. Kurtz, J.A. Ochoa, E. Lau et al.Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1992-2006. Paeing Clin Electrophysiol, 33:705.
  • 9Voigt A, Shalaby A, Saba S. Rising tales of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coil Cardiol, 2000;48:590.
  • 10Klug D, Balde M, Pavin D et al. Risk factors related to infections of implanted p emakers and cardioverter-defibrillators: results of a large prospective study. Circulation, 116:1349.