不同火源位置的火灾危险性模拟研究 被引量:6

Simulation of fire hazard of different fire location
下载PDF
导出
摘要 分析某大型餐厅的火灾危险性,设定不同火源位置下的火灾场景,利用火灾模拟动力学软件FDS结合人员疏散的经验公式,计算相应的可用疏散时间与必须疏散时间,得出安全评价结果。结果表明:同样的火灾功率,不同火源位置的火灾场景下的疏散情况有很大不同;机械排烟系统对火灾蔓延控制十分重要。建议该餐厅加大排烟能力,增设安全出口。 Fire risk of a large restaurant was analyzed. Scenarios were set under different fire place. FDS and empirical formula were used to calculate TASET and TRSET. The results of safety e- valuation was obtained which showed that: fire evacuation un- der fire scene was very different with the same fire power and the different location; mechanical ventilation is important for controlling fire spreading. Suggestions including increasing the capability of smoke exhausting, and adding exit were made.
出处 《消防科学与技术》 CAS 北大核心 2016年第3期313-315,共3页 Fire Science and Technology
基金 国家科技基础性工作专项项目(2015FY410100) 公安部公安理论及软科学研究计划项目(2014LLYJGASX063) 河南省科技攻关计划项目(152102310375) 郑州轻工业学院博士科研基金项目(2013BSJJ029) 广东省消防科学技术重点实验室开放基金项目(2015A02 2016A01) 国家自然科学基金项目(51404216) 河南省高等学校青年骨干教师计划项目(2015GGJS-184)
关键词 餐厅 火灾 火源 人员疏散 数值模拟 restaurant fire fire source safety evacuation mathematical simulation
  • 相关文献

参考文献4

二级参考文献17

  • 1[1]H E Feustel, C H Zuercher, R Diamond, et al. Temperature and Wind Induced Air Flow Patterns in a Staircase Computer Modeling and Experimental Verification. Energy Buildings, 1985, 8:105-122
  • 2[2]S B Riffat, J Walker, J Litter. Zone to Zone Tracer Gas Measurements Laboratory Calibration and Values of Air Flows Up and Down Stairs in Houses. In: Proceedings of the 9th AIVC Conference. 1988. 85-101
  • 3[3]R Edwards, C Irwin. Two-Directional Air Movements in Stairwells. In: 11th AIVC Conference. 1990, 21:379-388
  • 4[4]A S Zohrabian, M R Mokhtarzadeh Dehghan, A J Reynolds. Buoyancy-Driven Air Flow in a Stairwell Model with Through-Flow. Energy Buildings, 1990, 14:133-142
  • 5[5]A S Zohrabian, M R Mokhtarzadeh-Dehghan, A J Reynolds, et al. An experimental Study of BuoyancyDriven Flow in a Half-Scale Stairwell Model. Building Envir., 1989, 24(2): 141-148
  • 6[6]A A Peppes, M Santamouris, D N Asimakopoulos.Buoyancy-Driven Flow Through a Stairwell. Building and Environment, 2001, 36:167-180
  • 7[7]A A Peppes, M Santamouris, D N Asimakopoulos. Experimental and Numerical Study of Buoyancy-Driven Stairwell Flow in a Three Storey Building. Building and Environment, 2002, 37:497-506
  • 8[8]N R Marshall. The Behaviour of Hot Gases Flowing Within a Staircase. Fire Safety J., 1985, 9:245-255
  • 9[9]S Ergin Ozkan, M R Mokhtarzadeh-Dehghan, A J Reynolds. The Effect of Different Air Inlet Sizes on the Air Flow Through a Stairwell. Indoor Evir., 1993, 2(5/6):350-359
  • 10[10]S Ergin Ozkan, M R Mokhtarzadeh Dehghan, A J Reynolds. Experimental Study of Natural Convection Between Two Compartments of a Stairwell. Heat Mass Transfer, 1995, 38(12): 2159-2168

共引文献156

同被引文献45

引证文献6

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部