介绍冰雪世界工程的消防设计,针对项目存在的防火分区面积大、人员疏散距离长等超出国家现行消防设计标准的问题提出优化设计方案。优化方案采取的措施包括采用防火墙及防火玻璃加自动喷水防护冷却保护系统进行防火分隔,控制游客数量,增设疏散楼梯及消防设施等。通过对不同火灾场景和人员疏散场景的分析,论证消防设计方案的可行性。
The fire protection design of an ice-snow world was introduced, According to the problems that cannot meet the re- quirement of Code, like large area of fire compartmentation, long distance of evacuation, the optimized scheme was pro- posed. The measures in the optimized scheme included using fire wall and fire glasses with automatic water spray cooling protection system as fire separation, controlling the number of tourist, adding the evacuation staircase and fire protection facil- ities, etc. The feasibility of fire protection design was demon- strated by analysis of fire scenarios and evacuation scenarios.
出处
《消防科学与技术》
CAS
北大核心
2016年第3期365-367,共3页
Fire Science and Technology
关键词
建筑防火
冰雪乐园
防火分区
人员疏散
消防
设施
防火玻璃
冷却防护
building fire protection
ice-snow park
fire compar- tmentation
person evacuation
fire facility
fire glasses
cool- ing protection