武钢热轧总厂二分厂1#加热炉改造实践 被引量:1

The reformative repairment of WISCO HSM2 1~# reheating furnace
下载PDF
导出
摘要 通过对武钢热轧总厂二分厂1#加热炉的改造性大修,优化了加热炉炉型结构,升级了加热炉燃烧系统设备及控制系统,改善了炉区操作环境。改造后的1#加热炉经过近1a的运行,能耗显著降低,加热质量明显提高,操作环境有效改善,达到了改造预期目的。 Through the reformative repairment of WISCO HSM2 1~# reheating furnace,the structure of 1~# reheating furnace were optimized,the combustion equipments and the control system of the furnace were upgraded Comprehensively,the operating environment of the furnace were improved.After nearly one years running of the upgraded 1~# heating furnace,the energy consumption were decreased significantly,the steel billet heating quality were improved obviously,and the operation environment were improved effectively.The desired purpose of the reformative repairment were achieved.
出处 《节能》 2016年第2期68-71,共4页 Energy Conservation
关键词 加热炉 改造性大修 能耗 操作环境 加热质量 reheating furnace reformative repair energy consumption operating environment heating quality